Single-Surgeon Direct Comparison of O-arm Neuronavigation versus Mazor X Robotic-Guided Posterior Spinal Instrumentation

We sought to compare intraoperative surgical instrumentation techniques with image-guidance versus robotic-guided procedures for posterior spinal fusion. A retrospective review of institutional data collected from a single surgeon was used to compare surgical outcomes between O-arm neuronavigation a...

Full description

Saved in:
Bibliographic Details
Published inWorld neurosurgery Vol. 137; pp. e278 - e285
Main Authors Mao, Gordon, Gigliotti, Michael J., Myers, Daniel, Yu, Alexander, Whiting, Donald
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.05.2020
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:We sought to compare intraoperative surgical instrumentation techniques with image-guidance versus robotic-guided procedures for posterior spinal fusion. A retrospective review of institutional data collected from a single surgeon was used to compare surgical outcomes between O-arm neuronavigation and the Mazor X robotic-assistance system for placement of posterior spinal instrumentation in a consecutive series of patients. Univariate statistical significance testing compared time spent in the operating room, blood loss, screw accuracy, and wound healing. Between January 2017 and February 2019, 46 O-arm cases (mean age 59.6 years ± 13.7 years) and 39 Mazor X cases (mean age 59.5 years ± 12.4 years) were conducted. Cases were classified as degenerative, infectious, oncologic, and trauma with a mean of 4.57 and 5.43 levels operated on using O-arm neuronavigation and Mazor X, respectively. Mean operative times (P = 0.124), estimated blood loss (P = 0.212), wound revision rates (P = 0.560), and clinically acceptable instrumentation placement (P = 0.076) did not demonstrate significance between the 2 groups. However, screw placement was significantly more accurate and precise (P = 1 × 10–9) with robotic assistance when considering Gertzbein-Robbins A placement. Although a trend toward greater accuracy was noticed with robotic technology when determining clinically acceptable screws, there was not a significant difference when compared with O-arm neuronavigation. However, robotic technology has a significant effect on both precision and accuracy in Gertzbein-Robbins A screw placement. Robotics does not have a clear advantage when discussing infection rates, intraoperative blood loss, or operative time.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1878-8750
1878-8769