Distraction forces on the spine in early-onset scoliosis: A systematic review and meta-analysis of clinical and biomechanical literature
Distraction-based growing rods are frequently used to treat Early-Onset Scoliosis. These use intermittent spinal distractions to maintain correction and allow for growth. It is unknown how much spinal distraction can be applied safely. We performed a systematic review and meta-analysis of clinical a...
Saved in:
Published in | Journal of biomechanics Vol. 124; p. 110571 |
---|---|
Main Authors | , , , , , , |
Format | Journal Article |
Language | English |
Published |
Kidlington
Elsevier Ltd
19.07.2021
Elsevier Limited |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Distraction-based growing rods are frequently used to treat Early-Onset Scoliosis. These use intermittent spinal distractions to maintain correction and allow for growth. It is unknown how much spinal distraction can be applied safely. We performed a systematic review and meta-analysis of clinical and biomechanical literature to identify such safety limits for the pediatric spine.
This systematic review and meta-analysis was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Three systematic searches were performed including in-vivo, ex-vivo and in-silico literature. Study quality was assessed in all studies and data including patient- or specimen characteristics, distraction magnitude and spinal failure location and ultimate force at failure were collected. Twelve studies were included, 6 in-vivo, 4 ex-vivo and 2 in-silico studies. Mean in-vivo distraction forces ranged between 242 and 621 N with maxima of 422–981 N, without structural failures when using pedicle screw constructs. In the ex-vivo studies (only cervical spines), segment C0-C2 was strongest, with decreasing strength in more distal segments. Meta-regression analysis demonstrated that ultimate force at birth is 300–350 N, which increases approximately 100 N each year until adulthood. Ex-vivo and in-silico studies showed that yielding occurs at 70–90% of ultimate force, failure starts at the junction between endplate and intervertebral disc, after which the posterior- and anterior long ligament rupture. While data on safety of distraction forces is limited, this systematic review and meta-analysis may aid in the development of guidelines on spinal distraction and may benefit the development and optimization of contemporary and future distraction-based technologies. |
---|---|
Bibliography: | ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-1 content type line 23 ObjectType-Undefined-3 |
ISSN: | 0021-9290 1873-2380 |
DOI: | 10.1016/j.jbiomech.2021.110571 |