Modification of the centerline method for assessment of echocardiographic wall thickening and motion: A comparison with areas of risk

The abilility of the centerline method to discern regional myocardial risk area was evaluated using two-dimensional echocardiographic measurements and coronary artery occlusion in 16 open chest, anesthetized dogs. The centerline method was modified to allow determination of both wall thickening and...

Full description

Saved in:
Bibliographic Details
Published inJournal of the American College of Cardiology Vol. 11; no. 4; pp. 861 - 866
Main Authors McGillem, Mark J, Mancini, G.B.John, DeBoe, Scott F, Buda, Andrew J
Format Journal Article
LanguageEnglish
Published New York, NY Elsevier Inc 01.04.1988
Elsevier Science
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The abilility of the centerline method to discern regional myocardial risk area was evaluated using two-dimensional echocardiographic measurements and coronary artery occlusion in 16 open chest, anesthetized dogs. The centerline method was modified to allow determination of both wall thickening and wall motion at control and during coronary artery occlusion. End-systolic and end-diastolic echocardiographic images were analyzed at 100 equally spaced points around the centreline of the short axis view of the left ventricle to determine shortening and thickening abnormalities. In vivo risk regions were assessed by microsphere injection during occlusion, and autoradiographic analysis revealed a mean (± SD) circumferential risk area of 37.5± 7.7%. Abnormal function was established by three criteria on the basis of the control values for both fractional shortening and wall thickening: 1) <2 SD, 2) <95% tolerance limits, and 3) dyskinesia. The criterion of <2 SD estimated a risk area of 45.9 ± 16.7 % for fractional shortening and 37.2 ± 16.8% for wall thickening. Although neither value was significantly different from the actual mean value for the risk region, the results for fractional shortening were greater than for wall thickening (p < 0.01). The <95% tolerance limit method significantly underestimated risk area for both shortening (25.6 ± 15.1%, p < 0.05) and thickening (19.1 ± 12.7%, p < 0.001), as did analysis by dyskinesia (13.1± 12.1% for shortening, p < 0.0001), 20.6 ± 12.1% for thickening, p < 0.01). Thus, modification of the centerline method allowed determination of both fractional shortening and wall thickening from echocardiographic images. Analysis by the criterion of <2 SD most closely approximated actual risk area, and analysis of shortening yielded larger areas of abnormality than did analysis of thickening.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0735-1097
1558-3597
DOI:10.1016/0735-1097(88)90223-9