Three-dimensional optimization and sensitivity analysis of dental implant thread parameters using finite element analysis

This study aimed to optimize the thread depth and pitch of a recently designed dental implant to provide uniform stress distribution by means of a response surface optimization method available in finite element (FE) software. The sensitivity of simulation to different mechanical parameters was also...

Full description

Saved in:
Bibliographic Details
Published inJournal of the Korean Association of Oral and Maxillofacial Surgeons Vol. 44; no. 2; pp. 59 - 65
Main Authors Geramizadeh, Maryam, Katoozian, Hamidreza, Amid, Reza, Kadkhodazadeh, Mahdi
Format Journal Article
LanguageEnglish
Published Korea (South) The Korean Association of Oral and Maxillofacial Surgeons 01.04.2018
대한구강악안면외과학회
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:This study aimed to optimize the thread depth and pitch of a recently designed dental implant to provide uniform stress distribution by means of a response surface optimization method available in finite element (FE) software. The sensitivity of simulation to different mechanical parameters was also evaluated. A three-dimensional model of a tapered dental implant with micro-threads in the upper area and V-shaped threads in the rest of the body was modeled and analyzed using finite element analysis (FEA). An axial load of 100 N was applied to the top of the implants. The model was optimized for thread depth and pitch to determine the optimal stress distribution. In this analysis, micro-threads had 0.25 to 0.3 mm depth and 0.27 to 0.33 mm pitch, and V-shaped threads had 0.405 to 0.495 mm depth and 0.66 to 0.8 mm pitch. The optimized depth and pitch were 0.307 and 0.286 mm for micro-threads and 0.405 and 0.808 mm for V-shaped threads, respectively. In this design, the most effective parameters on stress distribution were the depth and pitch of the micro-threads based on sensitivity analysis results. Based on the results of this study, the optimal implant design has micro-threads with 0.307 and 0.286 mm depth and pitch, respectively, in the upper area and V-shaped threads with 0.405 and 0.808 mm depth and pitch in the rest of the body. These results indicate that micro-thread parameters have a greater effect on stress and strain values.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2234-7550
2234-5930
DOI:10.5125/jkaoms.2018.44.2.59