Technical considerations on the validity of blood oxygenation level-dependent-based MR assessment of vascular deoxygenation

A blood oxygenation level‐dependent (BOLD)‐based apparent relative oxygen extraction fraction (rOEF) as a semi‐quantitative marker of vascular deoxygenation has recently been introduced in clinical studies of patients with glioma and stroke, yielding promising results. These rOEF measurements are ba...

Full description

Saved in:
Bibliographic Details
Published inNMR in biomedicine Vol. 27; no. 7; pp. 853 - 862
Main Authors Hirsch, Nuria M., Toth, Vivien, Förschler, Annette, Kooijman, Hendrik, Zimmer, Claus, Preibisch, Christine
Format Journal Article
LanguageEnglish
Published England Blackwell Publishing Ltd 01.07.2014
Wiley Subscription Services, Inc
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:A blood oxygenation level‐dependent (BOLD)‐based apparent relative oxygen extraction fraction (rOEF) as a semi‐quantitative marker of vascular deoxygenation has recently been introduced in clinical studies of patients with glioma and stroke, yielding promising results. These rOEF measurements are based on independent quantification of the transverse relaxation times T2 and T2* and relative cerebral blood volume (rCBV). Simulations demonstrate that small errors in any of the underlying measures may result in a large deviation of the calculated rOEF. Therefore, we investigated the validity of such measurements. For this, we evaluated the quantitative measurements of T2 and T2* at 3 T in a gel phantom, in healthy subjects and in healthy tissue of patients with brain tumors. We calculated rOEF maps covering large portions of the brain from T2, T2* and rCBV [routinely measured in patients using dynamic susceptibility contrast (DSC)], and obtained rOEF values of 0.63 ± 0.16 and 0.90 ± 0.21 in healthy‐appearing gray matter (GM) and white matter (WM), respectively; values of about 0.4 are usually reported. Quantitative T2 mapping using the fast, clinically feasible, multi‐echo gradient spin echo (GRASE) approach yields significantly higher values than much slower multiple single spin echo (SE) experiments. Although T2* mapping is reliable in magnetically homogeneous tissues, uncorrectable macroscopic background gradients and other effects (e.g. iron deposition) shorten T2*. Cerebral blood volume (CBV) measurement using DSC and normalization to WM yields robust estimates of rCBV in healthy‐appearing brain tissue; absolute quantification of the venous fraction of CBV, however, is difficult to achieve. Our study demonstrates that quantitative measurements of rOEF are currently biased by inherent difficulties in T2 and CBV quantification, but also by inadequacies of the underlying model. We argue, however, that standardized, reproducible measurements of apparent T2, T2* and rCBV may still allow the estimation of a meaningful apparent rOEF, which requires further validation in clinical studies. Copyright © 2014 John Wiley & Sons, Ltd. The validity of the apparent relative oxygen extraction fraction (rOEF) measurements based on the independent quantification of the transverse relaxation times T2 and T2*, as well as the relative cerebral blood volume (rCBV), is investigated. True quantitative measurements are not possible using this fast method in a clinical setting. The reasons are constraints with regard to CBV quantification, multiple influences on T2* relaxation, sequence dependence of T2 values and inadequacies of the model. Qualitative rOEF imaging may nevertheless serve as a valuable surrogate marker of tissue hypoxia.
Bibliography:ark:/67375/WNG-N53JVTC4-8
istex:EDD13B7A62EC782B2134512D98880F0AA2CEA92C
ArticleID:NBM3131
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ObjectType-Article-2
ObjectType-Feature-1
ISSN:0952-3480
1099-1492
1099-1492
DOI:10.1002/nbm.3131