Comparison of visual outcomes in adult patients with different types of developmental cataracts after toric multifocal intraocular lenses implantation

Purpose  To analyze and compare the visual performance and patient satisfaction following the implantation of toric multifocal intraocular lenses (TMIOLs) in adult patients with different types of developmental cataracts (DC) accompanied by corneal astigmatism (CA). Methods  This is a prospective ob...

Full description

Saved in:
Bibliographic Details
Published inGraefe's archive for clinical and experimental ophthalmology Vol. 261; no. 12; pp. 3521 - 3530
Main Authors Shen, Jiying, Ma, Dongmei, Cai, Lei, Zhang, Limei, Guo, Haike, Yang, Jin
Format Journal Article
LanguageEnglish
Published Berlin/Heidelberg Springer Berlin Heidelberg 01.12.2023
Springer Nature B.V
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Purpose  To analyze and compare the visual performance and patient satisfaction following the implantation of toric multifocal intraocular lenses (TMIOLs) in adult patients with different types of developmental cataracts (DC) accompanied by corneal astigmatism (CA). Methods  This is a prospective observational cohort study. Patients diagnosed with DC aged 18–30 years were divided into three groups according to the anatomic location of the lens opacity: cortical, nuclear, and posterior subcapsular (PSC) groups, and implanted with TMIOLs. Visual acuity (VA), postoperative refractive astigmatism (RA), intraocular lens (IOL) rotation, high-order aberrations (HOAs), modulation transfer function (MTF) curve, and Strehl ratio were compared. The functional vision and incidence of photic phenomena were surveyed using questionnaires. Results  Fifty-five eyes of 37 patients were enrolled and completed a 1-year follow-up. The mean CA was 2.06 ± 0.79 D preoperatively, and the mean RA was 0.29 ± 0.30 D 3-month postoperatively. The IOL rotation was 2.48° ± 1.89°, with no deviation > 10°. At 12 months, mean uncorrected distance VA improved from 0.93 ± 0.41 preoperatively to 0.08 ± 0.08 logarithm of the minimum angle of resolution (logMAR), mean uncorrected near VA increased from 0.45 ± 0.30 preoperatively to 0.12 ± 0.11 logMAR, and mean uncorrected intermediate VA was 0.14 ± 0.08 logMAR. The cortical and nuclear groups displayed better improvements in uncorrected near and intermediate VA than that in the PSC group. Similar results were observed in the 3-month defocus curves, HOAs, MTF curve, halo incidence, and near vision satisfaction. Conclusion In adult patients with DC accompanied by CA, TMIOLs implantation achieved good postoperative visual outcomes and significantly reduced glasses dependency. Patients with cortical or nuclear lens opacity showed better whole-course VA and quality of vision, while patients with PSC opacity showed unsatisfactory near vision and suffered more photic phenomena.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Undefined-3
ISSN:0721-832X
1435-702X
DOI:10.1007/s00417-023-06148-4