Development of a cloud-based flow rate tool for eNAMPT biomarker detection

Increased levels of extracellular nicotinamide phosphoribosyltransferase (eNAMPT) are increasingly recognized as a highly useful biomarker of inflammatory disease and disease severity. In preclinical animal studies, a monoclonal antibody that neutralizes eNAMPT has been generated to successfully red...

Full description

Saved in:
Bibliographic Details
Published inPNAS nexus Vol. 3; no. 5; p. pgae173
Main Authors Buchanan, Bailey C, Tang, Yisha, Lopez, Hannah, Casanova, Nancy G, Garcia, Joe G N, Yoon, Jeong-Yeol
Format Journal Article
LanguageEnglish
Published England Oxford University Press 01.05.2024
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Increased levels of extracellular nicotinamide phosphoribosyltransferase (eNAMPT) are increasingly recognized as a highly useful biomarker of inflammatory disease and disease severity. In preclinical animal studies, a monoclonal antibody that neutralizes eNAMPT has been generated to successfully reduce the extent of inflammatory cascade activation. Thus, the rapid detection of eNAMPT concentration in plasma samples at the point of care (POC) would be of great utility in assessing the benefit of administering an anti-eNAMPT therapeutic. To determine the feasibility of this POC test, we conducted a particle immunoagglutination assay on a paper microfluidic platform and quantified its extent with a flow rate measurement in less than 1 min. A smartphone and cloud-based Google Colab were used to analyze the flow rates automatically. A horizontal flow model and an immunoagglutination binding model were evaluated to optimize the detection time, sample dilution, and particle concentration. This assay successfully detected eNAMPT in both human whole blood and plasma samples (diluted to 10 and 1%), with the limit of detection of 1-20 pg/mL (equivalent to 0.1-0.2 ng/mL in undiluted blood and plasma) and a linear range of 5-40 pg/mL. Furthermore, the smartphone POC assay distinguished clinical samples with low, mid, and high eNAMPT concentrations. Together, these results indicate this POC assay, which utilizes low-cost materials, time-effective methods, and a straightforward immunoassay (without surface immobilization), may reliably allow rapid determination of eNAMPT blood/plasma levels to advantage patient stratification in clinical trials and guide ALT-100 mAb therapeutic decision-making.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Competing Interest: The authors declare no competing interest.
Bailey C Buchanan and Yisha Tang contributed equally.
ISSN:2752-6542
2752-6542
DOI:10.1093/pnasnexus/pgae173