Paper based colorimetric detection of miRNA-21 using Ag/Pt nanoclusters

Abnormal expression of MicroRNA-21 (miRNA-21) is considered to be a reliable biomarker for the early diagnosis of cancer. In this work, a novel paper based biosensor was fabricated to detect sub-micro molar concentrations of miRNA-21 based on peroxidase mimetic activity of DNA-templated Ag/Pt nanocl...

Full description

Saved in:
Bibliographic Details
Published inSpectrochimica acta. Part A, Molecular and biomolecular spectroscopy Vol. 227; p. 117529
Main Authors Fakhri, Neda, Abarghoei, Shima, Dadmehr, Mehdi, Hosseini, Morteza, Sabahi, Hossein, Ganjali, Mohammad Reza
Format Journal Article
LanguageEnglish
Published England Elsevier B.V 15.02.2020
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Abnormal expression of MicroRNA-21 (miRNA-21) is considered to be a reliable biomarker for the early diagnosis of cancer. In this work, a novel paper based biosensor was fabricated to detect sub-micro molar concentrations of miRNA-21 based on peroxidase mimetic activity of DNA-templated Ag/Pt nanoclusters (DNA-Ag/Pt NCs), which could catalyze the reaction of hydrogen peroxide and 3,3′,5,5′ tetramethylbenzidine (TMB), to produce a blue color. The Mechanism of reaction was based on the inhibition effect of miRNA-21 on peroxidase-like activity of nanosensor which resulted to quantitative determination of miRNA-21 concentration. It was found that miRNA-21 could be linearly detected in the range from 1-700 pM (A652 = 0.16x-0.96, R2 = 0.99; x = -log [miRNA-21]) with a detection limit of 0.6 pM. Moreover, a paper assay was carried out on a Y-shaped paper-based microfluidic device in order to use the distinctive features of micro-channels such as short response time, very low reagent volume, low fabrication cost, etc. After performing paper based assay, a good linear range was observed between 10-1000 pM (y = 0.06x+147.48, R2 = 0.99; x = [miRNA-21]) with detection limit of 4.1 pM. The practical application of proposed method for detection of miRNA-21 in real sample was assayed in the human urine sample and indicated the colorimetric method had acceptable accuracy. [Display omitted] •A novel paper-based microfluidic sensor was designed for detection of miRNA-21.•The miRNA-21 detection mechanism is based on peroxidase mimetic activity of DNA-Ag/Pt NCs.•The color change was obvioused in different concentration of miRNA-21.•This strategy shows excellent selectivity toward miR-21.
ISSN:1386-1425
1873-3557
DOI:10.1016/j.saa.2019.117529