Reliability of the disk damage likelihood scale

To report the reliability of the glaucoma disk damage likelihood scale (DDLS) in comparison to the Armaly cup/disk ratio by determining the interobserver and intraobserver agreement for optic disk stereo photographs and the interobserver agreement for in vivo patient measurements of the optic disk....

Full description

Saved in:
Bibliographic Details
Published inAmerican journal of ophthalmology Vol. 135; no. 1; pp. 44 - 48
Main Authors Henderer, Jeffrey D, Liu, Connie, Kesen, Muge, Altangerel, Undraa, Bayer, Atilla, Steinmann, William C, Spaeth, George L
Format Journal Article
LanguageEnglish
Published New York, NY Elsevier Inc 01.01.2003
Elsevier
Elsevier Limited
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:To report the reliability of the glaucoma disk damage likelihood scale (DDLS) in comparison to the Armaly cup/disk ratio by determining the interobserver and intraobserver agreement for optic disk stereo photographs and the interobserver agreement for in vivo patient measurements of the optic disk. Observational case series. Optic disk photographs: 48 stereo pairs of optic nerve photographs were selected from patients with a spectrum of glaucomatous visual field loss. Two masked observers graded the optic disk photographs three times according to the DDLS and Armaly cup/disk ratio. Interobserver and intraobserver agreements were calculated using the test–retest method. Patient measurements: three observers performed in vivo patient measurements on 34 eyes of glaucoma clinic patients and made a single determination of the DDLS stage and Armaly cup/disk ratio, based on the indirect biomicroscopic examination. Level of interobserver agreement was tabulated. Optic disk photographs: interobserver and intraobserver agreement for the vertical DDLS measurement was greater than for two determinations (clinical impression and measured) of the vertical Armaly cup/disk ratio (interobserver: 85% vs 68% and 74%, respectively; intraobserver grader 1: 97% vs 89% and 80%, grader 2: 99% vs 95% and 89%, respectively). In vivo patient measurements: the interobserver agreement for the DDLS and Armaly cup/disk ratio was similar (70.1% vs 67.6%, respectively). For the stereo optic disk photographs, the inter- and intra-observer agreement for the DDLS is greater than the Armaly cup/disk ratio. For the in vivo patient measurements, the level of agreement for the DDLS and the Armaly cup/disk ratio is similar.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0002-9394
1879-1891
DOI:10.1016/S0002-9394(02)01833-0