An empirical evaluation of temporal overheating in an assisted living Passivhaus dwelling in the UK

Global concern around energy use and anthropogenic climate change have resulted in an increased effort to reduce the energy demand and CO2 emissions attributable to buildings. This has led to the development of a number of low energy building standards, one of which is the internationally recognised...

Full description

Saved in:
Bibliographic Details
Published inBuilding and environment Vol. 121; pp. 106 - 118
Main Authors Fletcher, M.J., Johnston, D.K., Glew, D.W., Parker, J.M.
Format Journal Article
LanguageEnglish
Published Elsevier Ltd 15.08.2017
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Global concern around energy use and anthropogenic climate change have resulted in an increased effort to reduce the energy demand and CO2 emissions attributable to buildings. This has led to the development of a number of low energy building standards, one of which is the internationally recognised Passivhaus Standard. The Passivhaus Standard aims to reduce the space heating energy demand of a building by adopting a ‘fabric first’ approach, thus ensuring the thermal envelope is highly insulated and airtight whilst also maximising passive solar heat gains. However, adopting such an approach does present a risk of overheating; a situation that is of particular concern when the occupants have additional healthcare requirements. This study uses 21 months of in-use monitored data to consider the overheating risk in a UK Passivhaus dwelling with vulnerable occupants using both static and adaptive thermal comfort assessment methods. The analysis of the data suggests the occurrence of substantial overheating according to PHPP, CIBSE Guide A and CIBSE TM52 criteria. The analysis was then expanded to consider a novel composite method to overcome the limitations of existing approaches, allowing overheating to be assessed during non-typical periods i.e. the heating season. This revealed apparent overheating during colder months, in addition to substantial night-time overheating. This has implications for the thermal comfort assessment of low energy dwellings and the design and operation of Passivhaus buildings, particularly those with vulnerable occupants. •Passivhaus dwellings are at risk of overheating in all seasons.•Current methods are not effective in identifying overheating risk in all seasons.•A composite assessment method is proposed to assess annual overheating.•Passivhaus may be unsuitable for vulnerable occupants if operated inexpertly.
ISSN:0360-1323
1873-684X
DOI:10.1016/j.buildenv.2017.05.024