Electrospray ionization mass spectrometry of phosphopeptides isolated by on-line immobilized metal-ion affinity chromatography

Electrospray ionization mass spectrometry (ESI/MS) affords a rapid and sensitive technique for determining peptides produced by the enzymatic digestion of phosphoproteins. When coupled with on-line immobilized metal-ion affinity chromatography (IMAC), the combination allows separation and mass spect...

Full description

Saved in:
Bibliographic Details
Published inJournal of the American Society for Mass Spectrometry Vol. 4; no. 8; pp. 662 - 669
Main Authors Nuwaysir, Lydia M., Stults, John T.
Format Journal Article
LanguageEnglish
Published New York, NY Elsevier Inc 01.08.1993
Elsevier Science
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Electrospray ionization mass spectrometry (ESI/MS) affords a rapid and sensitive technique for determining peptides produced by the enzymatic digestion of phosphoproteins. When coupled with on-line immobilized metal-ion affinity chromatography (IMAC), the combination allows separation and mass spectrometric identification of phosphorylated and nonphosphorylated peptides. In this study, the feasibility and general applicability of on-line IMAC/ESI/MS is investigated by using immobilized ferric ions for selective chelation of several phosphotyrosine and phosphoserine peptides. The sensitivity and practicality of the technique for phosphoproteins are demonstrated via the analysis of 30 pmol (∼0.7 μg) of bovine β-casein purified by sodium dodecylsulfate-polyacrylamide gel electrophoresis, electroblotted onto a polyvinylidene difluoride membrane, and digested in situ with trypsin. It is observed that on-line IMAC/ESI/MS suffers less from sample losses than experiments performed off-line, suggesting that the limiting factors in sensitivity for this technique are the purification procedures and sample handling rather than the IMAC and mass spectrometry. Thus, the ability to inject the tryptic digest of an electroblotted protein directly onto the column without buffer exchange and to analyze the eluent directly via on-line coupling of the IMAC column to the mass spectrometer greatly reduces sample losses incurred through sample handling and provides a convenient method for analyzing phosphopeptides at low levels.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1044-0305
1879-1123
DOI:10.1016/1044-0305(93)85031-R