An online technique for monitoring the insulation condition of AC machine stator windings

A novel online technique for monitoring the insulation condition of ac machine stator windings is proposed in this paper. The concept is to measure the differential leakage currents of each phase winding from the terminal box in a noninvasive manner to assess the insulation condition during motor op...

Full description

Saved in:
Bibliographic Details
Published inIEEE transactions on energy conversion Vol. 20; no. 4; pp. 737 - 745
Main Authors Sang Bin Lee, Younsi, K., Kliman, G.B.
Format Journal Article
LanguageEnglish
Published New York IEEE 01.12.2005
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:A novel online technique for monitoring the insulation condition of ac machine stator windings is proposed in this paper. The concept is to measure the differential leakage currents of each phase winding from the terminal box in a noninvasive manner to assess the insulation condition during motor operation. The conventional differential CTs used for phase fault protection can be replaced with high performance current sensors to measure the leakage current with higher accuracy. Indicators for insulation condition such as the capacitance and dissipation factor are calculated based on the measurements to provide a low cost solution for online insulation condition assessment. A simplified online insulation system model is derived for analysis and interpretation of the measured data. Experimental results on a 15-hp induction motor under simulated insulation degradation conditions show that the proposed technique is a very sensitive method capable of detecting incipient signs of insulation degradation.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:0885-8969
1558-0059
DOI:10.1109/TEC.2005.853760