MRI issues for ballistic objects: information obtained at 1.5-, 3- and 7-Tesla

Abstract Background context Few studies exist for magnetic resonance imaging (MRI) issues and ballistics, and there are no studies addressing movement, heating, and artifacts associated with ballistics at 3-tesla (T). Movement because of magnetic field interactions and radiofrequency (RF)-induced he...

Full description

Saved in:
Bibliographic Details
Published inThe spine journal Vol. 13; no. 7; pp. 815 - 822
Main Authors Dedini, Russell D., MD, Karacozoff, Alexandra M., BS, Shellock, Frank G., PhD, Xu, Duan, MD, PhD, McClellan, R. Trigg, MD, Pekmezci, Murat, MD
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.07.2013
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Abstract Background context Few studies exist for magnetic resonance imaging (MRI) issues and ballistics, and there are no studies addressing movement, heating, and artifacts associated with ballistics at 3-tesla (T). Movement because of magnetic field interactions and radiofrequency (RF)-induced heating of retained bullets may injure nearby critical structures. Artifacts may also interfere with the diagnostic use of MRI. Purpose To investigate these potential hazards of MRI on a sample of bullets and shotgun pellets. Study design Laboratory investigation, ex vivo. Methods Thirty-two different bullets and seven different shotgun pellets, commonly encountered in criminal trauma, were assessed relative to 1.5-, 3-, and 7-T magnetic resonance systems. Magnetic field interactions, including translational attraction and torque, were measured. A representative sample of five bullets were then tested for magnetic field interactions, RF-induced heating, and the generation of artifacts at 3-T. Results At all static magnetic field strengths, non–steel-containing bullets and pellets exhibited no movement, whereas one steel core bullet and two steel pellets exhibited movement in excess of what might be considered safe for patients in MRI at 1.5-, 3- and 7-Tesla. At 3-T, the maximum temperature increase of five bullets tested was 1.7°C versus background heating of 1.5°C. Of five bullets tested for artifacts, those without a steel core exhibited small signal voids, whereas a single steel core bullet exhibited a very large signal void. Conclusions Ballistics made of lead with copper or alloy jackets appear to be safe with respect to MRI-related movement at 1.5-, 3-, and 7-T static magnetic fields, whereas ballistics containing steel may pose a danger if near critical body structures because of strong magnetic field interactions. Temperature increases of selected ballistics during 3-T MRI was not clinically significant, even for the ferromagnetic projectiles. Finally, ballistics containing steel generated larger artifacts when compared with ballistics made of lead with copper and alloy jackets and may impair the diagnostic use of MRI.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1529-9430
1878-1632
DOI:10.1016/j.spinee.2013.02.068