Accuracy of biplane long-axis left ventricular volume determined by cine magnetic resonance imaging in patients with regional and global dysfunction

Left ventricular (LV) volumes and ejection fraction can be obtained by applying Simpson's rule to multiple short-axis tomographic planes. A simpler method for determining LV volumes using the area-length equation is widely accepted and requires less time to acquire and analyze. Its accuracy, ho...

Full description

Saved in:
Bibliographic Details
Published inThe American journal of cardiology Vol. 77; no. 12; pp. 1098 - 1104
Main Authors Lawson, Mark A., Blackwell, Gerald G., Davis, Nancy D., Roney, Maryann, Dell'ltalia, Louis J., Pohost, Gerald M.
Format Journal Article
LanguageEnglish
Published New York, NY Elsevier Inc 15.05.1996
Elsevier
Elsevier Limited
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Left ventricular (LV) volumes and ejection fraction can be obtained by applying Simpson's rule to multiple short-axis tomographic planes. A simpler method for determining LV volumes using the area-length equation is widely accepted and requires less time to acquire and analyze. Its accuracy, however, is questionable in deformed or asymmetrically contracting ventricles. This study compares biplane long-axis to serial short-axis computed LV volumes obtained by cine gradient-echo magnetic resonance imaging (MRI) in 2 distinct patient populations: (1) patients with global LV dysfunction, and (2) patients with regional LV dysfunction. A total of 114 patients were studied using both methods. Among 37 patients with global LV dysfunction, there was no statistically significant difference between methods (long axis vs short axis) for determining LV end-diastolic volume (203 ± 91 vs 201 ± 90 ml), endsystolic volume (142 ± 81 vs 141 ± 82 ml), and ejection fraction (33 ± 12 vs 33 ± 13%). However, in the 77 patients with regional dysfunction, LV end-diastolic volume was statistically slightly higher when obtained using the long-axis approach (157 ± 53 vs 152 ± 51 ml; p = 0.004). Otherwise, end-systolic volume (97 ± 49 vs 95 ± 49 ml) and ejection fraction (40 ± 13 vs 40 ± 13%) were similar (p = NS). The correlation between LV volumes and ejection fractions for both groups was excellent (r > 0.91). Thus, in this study group, biplane long-axis and serial short-axis computed LV volumes and ejection fractions were similar in patients with global or regional LV dysfunction. In critically ill patients unable to complete a comprehensive MRI examination, the biplane long-axis-derived volumes provide adequate data.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0002-9149
1879-1913
DOI:10.1016/S0002-9149(96)00140-3