Preoperative evaluation of live renal donors using multislice CT angiography

To determine the accuracy of multidetector row CT renal angiography in the preoperative evaluation of live kidney donors, and to identify potential pitfalls when reporting. Between July 1998 and June 2003, 74 consecutive live renal donors underwent contrast-enhanced multidetector row CT renal angiog...

Full description

Saved in:
Bibliographic Details
Published inClinical radiology Vol. 60; no. 7; pp. 771 - 777
Main Authors Johnson, J.E., Loveday, E.J., Archer, L.J., Lear, P., Thornton, M.J.
Format Journal Article
LanguageEnglish
Published Amsterdam Elsevier Ltd 01.07.2005
Elsevier
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:To determine the accuracy of multidetector row CT renal angiography in the preoperative evaluation of live kidney donors, and to identify potential pitfalls when reporting. Between July 1998 and June 2003, 74 consecutive live renal donors underwent contrast-enhanced multidetector row CT renal angiography before donor nephrectomy. The operative notes and radiological reports of all cases were reviewed retrospectively. Where a significant discrepancy was identified, the archived images were reviewed by two radiologists in the light of the intraoperative findings. A total of 12 discrepancies were identified in 11 of the 74 cases (15%). In the preoperative CT angiography reports, 4 accessory arteries, 6 early-branching renal arteries, 1 duplicated renal vein and 1 accessory ureter were not identified; 9 of these were evident on review, but were not detected at the time of reporting. In 3 cases (1 accessory artery, the duplicated renal vein and the accessory ureter), the anomaly was not visible on review of the CT angiographic data, even with the benefit of hindsight. Surgical feedback during the study period resulted in modifications to CT technique and improved performance. In the majority of cases, there was good correlation between preoperative CT renal angiography and operative findings. Most discrepancies were due either to an oversight by the reporting radiologist, or failure to fully appreciate the potential surgical significance of certain findings. Regular surgical feedback plays a valuable role in improving reporting accuracy and maintaining imaging standards.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ObjectType-Case Study-3
ObjectType-Article-1
ObjectType-Feature-4
ObjectType-Report-2
ISSN:0009-9260
1365-229X
DOI:10.1016/j.crad.2004.12.007