Deep Learning Estimation of 10-2 and 24-2 Visual Field Metrics Based on Thickness Maps from Macula OCT

To develop deep learning (DL) systems estimating visual function from macula-centered spectral-domain (SD) OCT images. Evaluation of a diagnostic technology. A total of 2408 10-2 visual field (VF) SD OCT pairs and 2999 24-2 VF SD OCT pairs collected from 645 healthy and glaucoma subjects (1222 eyes)...

Full description

Saved in:
Bibliographic Details
Published inOphthalmology (Rochester, Minn.) Vol. 128; no. 11; pp. 1534 - 1548
Main Authors Christopher, Mark, Bowd, Christopher, Proudfoot, James A., Belghith, Akram, Goldbaum, Michael H., Rezapour, Jasmin, Fazio, Massimo A., Girkin, Christopher A., De Moraes, Gustavo, Liebmann, Jeffrey M., Weinreb, Robert N., Zangwill, Linda M.
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.11.2021
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:To develop deep learning (DL) systems estimating visual function from macula-centered spectral-domain (SD) OCT images. Evaluation of a diagnostic technology. A total of 2408 10-2 visual field (VF) SD OCT pairs and 2999 24-2 VF SD OCT pairs collected from 645 healthy and glaucoma subjects (1222 eyes). Deep learning models were trained on thickness maps from Spectralis macula SD OCT to estimate 10-2 and 24-2 VF mean deviation (MD) and pattern standard deviation (PSD). Individual and combined DL models were trained using thickness data from 6 layers (retinal nerve fiber layer [RNFL], ganglion cell layer [GCL], inner plexiform layer [IPL], ganglion cell-IPL [GCIPL], ganglion cell complex [GCC] and retina). Linear regression of mean layer thicknesses were used for comparison. Deep learning models were evaluated using R2 and mean absolute error (MAE) compared with 10-2 and 24-2 VF measurements. Combined DL models estimating 10-2 achieved R2 of 0.82 (95% confidence interval [CI], 0.68–0.89) for MD and 0.69 (95% CI, 0.55–0.81) for PSD and MAEs of 1.9 dB (95% CI, 1.6–2.4 dB) for MD and 1.5 dB (95% CI, 1.2–1.9 dB) for PSD. This was significantly better than mean thickness estimates for 10-2 MD (0.61 [95% CI, 0.47–0.71] and 3.0 dB [95% CI, 2.5–3.5 dB]) and 10-2 PSD (0.46 [95% CI, 0.31–0.60] and 2.3 dB [95% CI, 1.8–2.7 dB]). Combined DL models estimating 24-2 achieved R2 of 0.79 (95% CI, 0.72–0.84) for MD and 0.68 (95% CI, 0.53–0.79) for PSD and MAEs of 2.1 dB (95% CI, 1.8–2.5 dB) for MD and 1.5 dB (95% CI, 1.3–1.9 dB) for PSD. This was significantly better than mean thickness estimates for 24-2 MD (0.41 [95% CI, 0.26–0.57] and 3.4 dB [95% CI, 2.7–4.5 dB]) and 24-2 PSD (0.38 [95% CI, 0.20–0.57] and 2.4 dB [95% CI, 2.0–2.8 dB]). The GCIPL (R2 = 0.79) and GCC (R2 = 0.75) had the highest performance estimating 10-2 and 24-2 MD, respectively. Deep learning models improved estimates of functional loss from SD OCT imaging. Accurate estimates can help clinicians to individualize VF testing to patients.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0161-6420
1549-4713
1549-4713
DOI:10.1016/j.ophtha.2021.04.022