Reproducibility of Nerve Fiber Layer Thickness Measurements Using Optical Coherence Tomography in Silicone Oil-Filled Eyes

Purpose: To evaluate the reproducibility of nerve fiber layer (NFL) thickness measurements by optical coherence tomography (OCT) in individuals with silicone oil-filled eyes. Methods: Eighteen patients who had undergone pars plana vitrectomy and silicone oil tamponade for retinal detachment were enr...

Full description

Saved in:
Bibliographic Details
Published inOphthalmologica (Basel) Vol. 215; no. 2; pp. 91 - 96
Main Authors Mastropasqua, Leonardo, Carpineto, Paolo, Ciancaglini, Marco, Falconio, Gennaro, Harris, Alon
Format Journal Article
LanguageEnglish
Published Basel, Switzerland Karger 01.03.2001
S. Karger AG
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Purpose: To evaluate the reproducibility of nerve fiber layer (NFL) thickness measurements by optical coherence tomography (OCT) in individuals with silicone oil-filled eyes. Methods: Eighteen patients who had undergone pars plana vitrectomy and silicone oil tamponade for retinal detachment were enrolled in a prospective, case-controlled clinical study. Each patient underwent OCT measurement of NFL thickness. Five repetitions of a series of scans on five separate occasions within a 0.5-month period were performed. Each eye was scanned at two different nerve head programs [radius (R) = 1.5 and R = 1.73]. The contralateral healthy eye was used as control. For each option (R = 1.5 and R = 1.73) and region (superior, inferior, temporal, nasal and overall mean), variance components and intraclass correlation coefficients (ICCs) were determined using repeated-measures regression. In these models, NFL thickness, as measured by OCT, was considered to have three variance components: intersubject, intervisit (within subject, between dates), and intravisit (within subject, within date). The ICC (intersubject variance/total variance) was used as a measure of reliability. Results: The contralateral healthy eye provided a higher degree of reproducibility than the silicone oil-filled eye (p = 0.0001). Reproducibility was higher in a given eye on a given visit than from visit to visit. Reproducibility as measured by ICCs was as follows: R = 1.5, 0.54/0.30 (control eyes/silicone oil-filled eyes); R = 1.73, 0.51/0.30. Conclusions: Reproducibility results for OCT measurement of NFL thickness are different in healthy eyes and silicone oil-filled eyes. NFL thickness measurement is not reliable in silicone oil-filled eyes.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ObjectType-Article-1
ObjectType-Feature-2
ISSN:0030-3755
1423-0267
DOI:10.1159/000050836