Specification and guideline for technical aspects and scanning parameter settings of neonatal lung ultrasound examination

Lung ultrasound (LUS) is now widely used in the diagnosis and monitor of neonatal lung diseases. Nevertheless, in the published literatures, the LUS images may display a significant variation in technical execution, while scanning parameters may influence diagnostic accuracy. The inter- and intra-ob...

Full description

Saved in:
Bibliographic Details
Published inThe journal of maternal-fetal & neonatal medicine Vol. 35; no. 5; pp. 1003 - 1016
Main Authors Liu, Jing, Guo, Guo, Kurepa, Dalibor, Volpicelli, Giovanni, Sorantin, Erich, Lovrenski, Jovan, Alonso-Ojembarrena, Almudena, Hsieh, Kai-Sheng, Lodha, Abhay, Yeh, Tsu F., Jagła, Mateusz, Shah, Heli, Yan, Wei, Hu, Cai-Bao, Zhou, Xiao-Guang, Guo, Rui-Jun, Cao, Hai-Ying, Wang, Yan, Zong, Hai-Feng, Shang, Li-Li, Ma, Hai-Ran, Liu, Ying, Fu, Wei, Shan, Rui-Yan, Qiu, Ru-Xin, Ren, Xiao-Ling, Copetti, Roberto, Rodriguez-Fanjul, Javier, Feletti, Francesco
Format Journal Article
LanguageEnglish
Published England Taylor & Francis 04.03.2022
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Lung ultrasound (LUS) is now widely used in the diagnosis and monitor of neonatal lung diseases. Nevertheless, in the published literatures, the LUS images may display a significant variation in technical execution, while scanning parameters may influence diagnostic accuracy. The inter- and intra-observer reliabilities of ultrasound exam have been extensively studied in general and in LUS. As expected, the reliability declines in the hands of novices when they perform the point-of-care ultrasound (POC US). Consequently, having appropriate guidelines regarding to technical aspects of neonatal LUS exam is very important especially because diagnosis is mainly based on interpretation of artifacts produced by the pleural line and the lungs. The present work aimed to create an instrument operation specification and parameter setting guidelines for neonatal LUS. Technical aspects and scanning parameter settings that allow for standardization in obtaining LUS images include (1) select a high-end equipment with high-frequency linear array transducer (12-14 MHz). (2) Choose preset suitable for lung examination or small organs. (3) Keep the probe perpendicular to the ribs or parallel to the intercostal space. (4) Set the scanning depth at 4-5 cm. (5) Set 1-2 focal zones and adjust them close to the pleural line. (6) Use fundamental frequency with speckle reduction 2-3 or similar techniques. (7) Turn off spatial compounding imaging. (8) Adjust the time-gain compensation to get uniform image from the near-to far-field.
ISSN:1476-7058
1476-4954
DOI:10.1080/14767058.2021.1940943