Electric field-assisted multiphase extraction to increase selectivity and sensitivity in liquid chromatography-mass spectrometry and paper spray mass spectrometry
In this work, for the first time, chromatographic paper was used for a multiphase extraction assisted by an electric field (MPEF) and directly coupled to paper spray mass spectrometry (PS-MS). Using this approach, five tricyclic antidepressants (TCAs) were determined in oral fluid. Firstly, the MPEF...
Saved in:
Published in | Talanta (Oxford) Vol. 224; p. 121887 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English |
Published |
Netherlands
Elsevier B.V
01.03.2021
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | In this work, for the first time, chromatographic paper was used for a multiphase extraction assisted by an electric field (MPEF) and directly coupled to paper spray mass spectrometry (PS-MS). Using this approach, five tricyclic antidepressants (TCAs) were determined in oral fluid. Firstly, the MPEF conditions were optimized using liquid chromatography-mass spectrometry (LC-MS/MS). The effects of the chromatographic paper and the types of electrolyte used in the acceptor phase, the organic solvent type and the amount used in the donor phase, the extraction time, and the applied electric potential were all investigated. After optimization, the analytes were extracted from the donor solution (sample and acetonitrile 1:1 (v/v)) over a period of 10 min at 300 V, crossing the free liquid membrane (1-octanol) and reaching the acceptor phase (chromatographic paper wetted with 400 mmol L−1 acetic acid). The method using LC-MS/MS was validated, demonstrating a linear range from 2 to 12 ng mL−1, with detection and quantification limits of 0.13–0.25 and 0.44–0.84 ng mL−1, respectively, an intraday precision of less than 20%, and no matrix effect observed. The optimized MPEF conditions were then applied to determine TCAs by PS-MS and for this analysis cyclobenzaprine was used as an internal standard. The easy, fast and direct approach of coupling MPEF with PS-MS analysis, as well as the pre-concentration and the low standard deviation of replicates (less than 20%), demonstrates that this method can be useful for screening in clinical and toxicological analysis.
[Display omitted]
•A novel multiphase extraction assisted by an electric field approach is presented.•Five tricyclic antidepressants were efficiently extracted from oral fluid.•LC-MS/MS after desorption and PS-MS directly coupled were used to determine the analytes.•Suitable pre-concentration factor and absence or low matrix effect were obtained. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0039-9140 1873-3573 |
DOI: | 10.1016/j.talanta.2020.121887 |