Diagnostic Accuracy of the Cepheid 3-gene Host Response Fingerstick Blood Test in a Prospective, Multi-site Study: Interim Results

Abstract Background The development of a fast and accurate, non-sputum-based point-of-care triage test for tuberculosis (TB) would have a major impact on combating the TB burden worldwide. A new fingerstick blood test has been developed by Cepheid (the Xpert MTB Host Response [MTB-HR] prototype), wh...

Full description

Saved in:
Bibliographic Details
Published inClinical infectious diseases Vol. 74; no. 12; pp. 2136 - 2141
Main Authors Sutherland, Jayne S, van der Spuy, Gian, Gindeh, Awa, Thuong, Nguyen Thuy Thuong, Namuganga, AnnRitah, Owolabi, Olumuyiwa, Mayanja-Kizza, Harriet, Nsereko, Mary, Thwaites, Guy, Winter, Jill, Dockrell, Hazel M, Scriba, Thomas J, Geluk, Annemieke, Corstjens, Paul, Stanley, Kim, Richardson, Tracy, Shaw, Jane A, Smith, Bronwyn, Malherbe, Stephanus T, Walzl, Gerhard
Format Journal Article
LanguageEnglish
Published US Oxford University Press 06.07.2022
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Abstract Background The development of a fast and accurate, non-sputum-based point-of-care triage test for tuberculosis (TB) would have a major impact on combating the TB burden worldwide. A new fingerstick blood test has been developed by Cepheid (the Xpert MTB Host Response [MTB-HR] prototype), which generates a “TB score” based on messenger RNA (mRNA) expression of 3 genes. Here we describe the first prospective findings of the MTB-HR prototype. Methods Fingerstick blood from adults presenting with symptoms compatible with TB in South Africa, The Gambia, Uganda, and Vietnam was analyzed using the Cepheid GeneXpert MTB-HR prototype. Accuracy of the Xpert MTB-HR cartridge was determined in relation to GeneXpert Ultra results and a composite microbiological score (GeneXpert Ultra and liquid culture) with patients classified as having TB or other respiratory diseases (ORD). Results When data from all sites (n = 75 TB, 120 ORD) were analyzed, the TB score discriminated between TB and ORD with an area under the curve (AUC) of 0.94 (95% confidence interval [CI], .91–.97), sensitivity of 87% (95% CI, 77–93%) and specificity of 94% (88–97%). When sensitivity was set at 90% for a triage test, specificity was 86% (95% CI, 75–97%). These results were not influenced by human immunodeficiency virus (HIV) status or geographical location. When evaluated against a composite microbiological score (n = 80 TB, 111 ORD), the TB score was able to discriminate between TB and ORD with an AUC of 0.88 (95% CI, .83–.94), 80% sensitivity (95% CI, 76–85%) and 94% specificity (95% CI, 91–96%). Conclusions Our interim data indicate the Cepheid MTB-HR cartridge reaches the minimal target product profile for a point of care triage test for TB using fingerstick blood, regardless of geographic area or HIV infection status. This study is the first prospective evaluation of the Cepheid MTB-HR test using fingerstick blood in a multi-site cohort. Interim results indicate the test reaches the WHO TPP for a TB Triage test regardless of geographical location and HIV status.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1058-4838
1537-6591
1537-6591
DOI:10.1093/cid/ciab839