Voltammetric determination of sibutramine in beverages and in pharmaceutical formulations
A simple and sensitive method has been proposed for the determination of sibutramine-HCl in energy drinks, green tea and pharmaceutical formulations using differential pulse voltammetry performed on a hanging mercury drop electrode. In the chosen experimental condition (Mcllvaine pH 4.0 buffer, 50 m...
Saved in:
Published in | Química Nova Vol. 35; no. 5; pp. 988 - 992 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
Sociedade Brasileira de Química
2012
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | A simple and sensitive method has been proposed for the determination of sibutramine-HCl in energy drinks, green tea and pharmaceutical formulations using differential pulse voltammetry performed on a hanging mercury drop electrode. In the chosen experimental condition (Mcllvaine pH 4.0 buffer, 50 mV pulse amplitude and 40 mV s-1 scan velocity), sibutramine-HCl presented a reversible behavior and a peak maximum at -80 mV. Detection limit was 0.4 mg L-1 and the working linear range extended up to 33.3 mg L-1 (r = 0.99). Analysis of real and fortified samples enabled recoveries between 91 and 102%. The electroanalytical method was compared with a HPLC method which indicated it accuracy. |
---|---|
ISSN: | 0100-4042 1678-7064 |