Accuracy of a Chest X-Ray–Based Method for Predicting the Depth of Insertion of Endotracheal Tubes in Pediatric Patients Undergoing Cardiac Surgery

Objectives The incidence of endotracheal tube (ETT) malposition in children with various described methods is 15% to 30%. Chest x-ray (CXR) is the gold standard for confirming appropriate ETT position. The aim of this study was to measure the accuracy of a preoperative CXR-based method in determinin...

Full description

Saved in:
Bibliographic Details
Published inJournal of cardiothoracic and vascular anesthesia Vol. 30; no. 4; pp. 947 - 953
Main Authors Koshy, Thomas, DA, MD, PDCC, FIACTA, FTEE, Misra, Satyajeet, MD, DNB, PDCC, TEE certified (EACVI), Chatterjee, Nilay, MD, DM, Dharan, Baiju S., MS, MCh
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.08.2016
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objectives The incidence of endotracheal tube (ETT) malposition in children with various described methods is 15% to 30%. Chest x-ray (CXR) is the gold standard for confirming appropriate ETT position. The aim of this study was to measure the accuracy of a preoperative CXR-based method in determining depth of insertion of ETTs and to compare it with methods based on the intubation depth mark or formulae (age, height, and ETT internal diameter) in children undergoing cardiac surgery. Design Prospective observational study. Setting University-affiliated tertiary care hospital. Participants Sixty-six consecutive children scheduled for elective pediatric cardiac surgery. Interventions None. Measurements and Main Results The distance from carina to mid-trachea was measured for each child preoperatively on the CXR displayed as a computed radiography image in a picture archival and communications system computer. Following intubation, ETTs deliberately were pushed endobronchially and then pulled back to the carina; they were further withdrawn by the previously measured carina to mid-tracheal distance and secured. CXRs postoperatively were repeated to confirm ETT position. The ETT position was measured with other methods using the picture archival and communications system ruler on the postoperative CXR and compared with the CXR method. The proportion of appropriate ETT position with the CXR method was 98.5% (p≤0.001 v other methods). In children younger than 3 years, the appropriate proportion was 97.4%. Conclusion The appropriate positioning of ETTs in the trachea by the CXR method is superior to other methods.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Undefined-1
ObjectType-Feature-3
content type line 23
ISSN:1053-0770
1532-8422
DOI:10.1053/j.jvca.2016.01.031