Textural interface opacity after Descemet-stripping automated endothelial keratoplasty

Purpose To describe cases of interface haze, also known as textural interface opacity, after Descemet-stripping automated endothelial keratoplasty (DSAEK). Setting Department of Cornea, External Disease, and Refractive Surgery Service, Duke Eye Center, Durham, North Carolina, USA. Design Retrospecti...

Full description

Saved in:
Bibliographic Details
Published inJournal of cataract and refractive surgery Vol. 40; no. 9; pp. 1514 - 1520
Main Authors Kim, Keunsoo, MD, PhD, Alder, Brian, MD, Vora, Gargi K., MD, Carlson, Alan N., MD, Afshari, Natalie A., MD, Kuo, Anthony N., MD, Kim, Terry, MD
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.09.2014
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Purpose To describe cases of interface haze, also known as textural interface opacity, after Descemet-stripping automated endothelial keratoplasty (DSAEK). Setting Department of Cornea, External Disease, and Refractive Surgery Service, Duke Eye Center, Durham, North Carolina, USA. Design Retrospective case series. Methods Patients' clinical and demographic characteristics, cornea donor information, surgical technique, histopathology, and anterior segment optical coherence tomography (OCT) were reviewed retrospectively and clinical outcomes reported. Results The interface haze that developed after DSAEK comprised 2 types of textural interface opacity; that is, total (11 cases) and partial (3 cases). The time of onset of textural interface opacity ranged from 1 day to 7 weeks postoperatively. Although most patients with textural interface opacity showed improvement, with a corrected distance visual acuity better than 20/50, 3 had persistent decreased visual acuity and required repeat DSAEK. Seven eyes had concurrent phacoemulsification with intraocular lens implantation and DSAEK. The corneal graft was inserted with an Endoserter device in 11 eyes, an insertion forceps in 2 eyes, and a cystotome needle in 1 eye. Histopathology of the grafts of eyes that required repeat DSAEK showed no inflammation, no foreign-body deposit, and no fibrosis. Anterior segment OCT showed increased hyperreflectivity in the interface. Conclusions Although the etiology of textural interface opacity is unclear, it may be related to retained ophthalmic viscosurgical device (OVD) or an adhesive property of the OVD used during the surgery. Although most cases resolve with time, repeat DSAEK may be an effective treatment for refractory cases. Financial Disclosure Dr. Kim is a consultant to Ocular Systems, Inc. No other author has a financial or proprietary interest in any material or method mentioned.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0886-3350
1873-4502
DOI:10.1016/j.jcrs.2013.12.020