Reduction of iodine load in CT imaging of pancreas acquired with low tube voltage and an adaptive statistical iterative reconstruction technique

To prospectively assess the contrast enhancement, image quality, radiation dose, and detectability of malignant pancreatic tumors with pancreatic computed tomography (CT) obtained at an 80-kilovolt (peak) (kV[p]) tube voltage setting and reduced iodine dose. Institutional review board approval and w...

Full description

Saved in:
Bibliographic Details
Published inJournal of computer assisted tomography Vol. 38; no. 5; p. 714
Main Authors Noda, Yoshifumi, Kanematsu, Masayuki, Goshima, Satoshi, Kondo, Hiroshi, Watanabe, Haruo, Kawada, Hiroshi, Kawai, Nobuyuki, Tanahashi, Yukichi, Miyoshi, Toshiharu, Bae, Kyongtae T
Format Journal Article
LanguageEnglish
Published United States 01.09.2014
Subjects
Online AccessGet more information

Cover

Loading…
More Information
Summary:To prospectively assess the contrast enhancement, image quality, radiation dose, and detectability of malignant pancreatic tumors with pancreatic computed tomography (CT) obtained at an 80-kilovolt (peak) (kV[p]) tube voltage setting and reduced iodine dose. Institutional review board approval and written informed consent were obtained. During a recent 10-month period, 136 patients (66 men and 70 women; age range, 21-86 years; mean ± SD age, 65.9 ± 11.0 years) with suspected pancreatic disease were randomized into 3 groups according to the following iodine-load and tube-voltage protocols: 600 mg of iodine per kilogram body weight (mg/kg) and 120 kV(p) (600-120 group), 500 mg/kg and 80 kV(p) (500-80 group), and 400 mg/kg and 80 kV(p) (400-80 group). Analysis of variance was conducted to evaluate differences in CT number, background noise, signal-to-noise ratio, effective dose, lesion-to-pancreas contrast-to-noise ratio, and figure of merit. Sensitivity, specificity, and area under the receiver-operating-characteristic curve were compared to assess the detectability of malignant pancreatic tumors. The signal-to-noise ratios in vessels were greater (P < 0.05) in the 400-80 and 500-80 groups than in the 600-120 group, and those in pancreas were comparable between the 400-80 and 600-120 groups. No significant difference was found in effective dose, image quality, lesion-to-pancreas contrast-to-noise ratio, or figure of merit between the groups. Sensitivity, specificity, and area under the receiver-operating-characteristic curve for detecting malignant pancreatic tumors were comparable between the groups. Pancreatic CT with an 80-kV(p) setting and 400-mg iodine per kilogram contrast material load facilitates the reduction of iodine dose while maintaining image quality and the detectability of malignant pancreatic tumors.
ISSN:1532-3145
DOI:10.1097/RCT.0000000000000106