Design and performance of the dilution cooler system for the Planck mission

We report the design, main features and on-ground qualification of the dilution cooler qualification model for the Planck mission. We mainly emphasize the innovative cryogenics and structural aspects developed in order to meet the severe requirements of the mission. We also report the results of the...

Full description

Saved in:
Bibliographic Details
Published inCryogenics (Guildford) Vol. 46; no. 4; pp. 288 - 297
Main Authors Triqueneaux, S., Sentis, L., Camus, Ph, Benoit, A., Guyot, G.
Format Journal Article
LanguageEnglish
Published Oxford Elsevier Ltd 01.04.2006
Elsevier
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:We report the design, main features and on-ground qualification of the dilution cooler qualification model for the Planck mission. We mainly emphasize the innovative cryogenics and structural aspects developed in order to meet the severe requirements of the mission. We also report the results of the dilution cooler itself in the 100 mK range after successful tests of the qualification model on a dedicated test bench.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:0011-2275
1879-2235