Effective Radiation Dose, Time, and Contrast Medium to Measure Fractional Flow Reserve
Objectives This study sought to define the additional effective radiation dose, procedural time, and contrast medium needed to obtain fractional flow reserve (FFR) measurements after a diagnostic coronary angiogram. Background The FFR measurements performed at the end of a diagnostic angiogram allow...
Saved in:
Published in | JACC. Cardiovascular interventions Vol. 3; no. 8; pp. 821 - 827 |
---|---|
Main Authors | , , , , , , , , , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
United States
Elsevier Inc
01.08.2010
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Objectives This study sought to define the additional effective radiation dose, procedural time, and contrast medium needed to obtain fractional flow reserve (FFR) measurements after a diagnostic coronary angiogram. Background The FFR measurements performed at the end of a diagnostic angiogram allow the obtaining of functional information that complements the anatomic findings. Methods In 200 patients (mean age 66 ± 10 years) undergoing diagnostic coronary angiography, FFR was measured in at least 1 intermediate coronary artery stenosis. Hyperemia was achieved by intracoronary (n = 180) or intravenous (n = 20) adenosine. The radiation dose (mSv), procedural time (min), and contrast medium (ml) needed for diagnostic angiography and FFR were recorded. Results A total of 296 stenoses (1.5 ± 0.7 stenoses per patient) were assessed. The additional mean radiation dose, procedural time, and contrast medium needed to obtain FFR expressed as a percentage of the entire procedure were 30 ± 16% (median 4 mSv, range 2.4 to 6.7 mSv), 26 ± 13% (median 9 min, range 7 to 13 min), and 31 ± 16% (median 50 ml, range 30 to 90 ml), respectively. The radiation dose and contrast medium during FFR were similar after intravenous and intracoronary adenosine, though the procedural time was slightly longer with intravenous adenosine (median 11 min, range 10 to 17 min, p = 0.04) than with intracoronary adenosine (median 9 min, range 7 to 13 min). When FFR was measured in 3 or more lesions, radiation dose, procedural time, and contrast medium increased. Conclusions The additional radiation dose, procedural time, and contrast medium to obtain FFR measurement are low as compared to other cardiovascular imaging modalities. Therefore, the combination of diagnostic angiography and FFR measurements is warranted to provide simultaneously anatomic and functional information in patients with coronary artery disease. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 1936-8798 1876-7605 |
DOI: | 10.1016/j.jcin.2010.06.006 |