Effective Radiation Dose, Time, and Contrast Medium to Measure Fractional Flow Reserve

Objectives This study sought to define the additional effective radiation dose, procedural time, and contrast medium needed to obtain fractional flow reserve (FFR) measurements after a diagnostic coronary angiogram. Background The FFR measurements performed at the end of a diagnostic angiogram allow...

Full description

Saved in:
Bibliographic Details
Published inJACC. Cardiovascular interventions Vol. 3; no. 8; pp. 821 - 827
Main Authors Ntalianis, Argyrios, MD, PhD, Trana, Catalina, MD, Muller, Olivier, MD, PhD, Mangiacapra, Fabio, MD, Peace, Aaron, MD, PhD, De Backer, Carina, RN, De Block, Liesbeth, RN, Wyffels, Eric, MD, Bartunek, Jozef, MD, PhD, Vanderheyden, Marc, MD, Heyse, Alex, MD, Van Durme, Frederic, MD, Van Driessche, Luc, MD, De Jans, Jo, RN, Heyndrickx, Guy R., MD, PhD, Wijns, William, MD, PhD, Barbato, Emanuele, MD, PhD, De Bruyne, Bernard, MD, PhD
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.08.2010
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objectives This study sought to define the additional effective radiation dose, procedural time, and contrast medium needed to obtain fractional flow reserve (FFR) measurements after a diagnostic coronary angiogram. Background The FFR measurements performed at the end of a diagnostic angiogram allow the obtaining of functional information that complements the anatomic findings. Methods In 200 patients (mean age 66 ± 10 years) undergoing diagnostic coronary angiography, FFR was measured in at least 1 intermediate coronary artery stenosis. Hyperemia was achieved by intracoronary (n = 180) or intravenous (n = 20) adenosine. The radiation dose (mSv), procedural time (min), and contrast medium (ml) needed for diagnostic angiography and FFR were recorded. Results A total of 296 stenoses (1.5 ± 0.7 stenoses per patient) were assessed. The additional mean radiation dose, procedural time, and contrast medium needed to obtain FFR expressed as a percentage of the entire procedure were 30 ± 16% (median 4 mSv, range 2.4 to 6.7 mSv), 26 ± 13% (median 9 min, range 7 to 13 min), and 31 ± 16% (median 50 ml, range 30 to 90 ml), respectively. The radiation dose and contrast medium during FFR were similar after intravenous and intracoronary adenosine, though the procedural time was slightly longer with intravenous adenosine (median 11 min, range 10 to 17 min, p = 0.04) than with intracoronary adenosine (median 9 min, range 7 to 13 min). When FFR was measured in 3 or more lesions, radiation dose, procedural time, and contrast medium increased. Conclusions The additional radiation dose, procedural time, and contrast medium to obtain FFR measurement are low as compared to other cardiovascular imaging modalities. Therefore, the combination of diagnostic angiography and FFR measurements is warranted to provide simultaneously anatomic and functional information in patients with coronary artery disease.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1936-8798
1876-7605
DOI:10.1016/j.jcin.2010.06.006