Feasibility of CT-guided Large-bore Biopsy of Lung Tumors with the Use of an Outer Sheath

Abstract Purpose To evaluate the feasibility, volume of biopsy specimens, and procedure-related tumor seeding of computed tomography (CT)–guided large-bore lung tumor biopsy through an outer sheath in advanced lung cancer. Materials and Methods Eighteen procedures were performed in 18 patients with...

Full description

Saved in:
Bibliographic Details
Published inJournal of vascular and interventional radiology Vol. 22; no. 5; pp. 699 - 701
Main Authors Izumi, Yotaro, MD, Nakatsuka, Seishi, MD, Asakura, Keisuke, MD, Soejima, Kenzo, MD, Nomori, Hiroaki, MD
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.05.2011
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Abstract Purpose To evaluate the feasibility, volume of biopsy specimens, and procedure-related tumor seeding of computed tomography (CT)–guided large-bore lung tumor biopsy through an outer sheath in advanced lung cancer. Materials and Methods Eighteen procedures were performed in 18 patients with established diagnosis of advanced or recurrent lung cancer. Biopsy specimens were obtained under local anesthesia and with fluoroscopic CT guidance. First, an outer sheath was placed in the tumor. Next, a semiautomatic cutting biopsy needle (14-gauge, n = 6; 12-gauge, n = 12) was inserted through the outer sheath, and the tumor biopsy specimen was obtained. After biopsy, the outer sheath was left in place for approximately 10 minutes, during which time hemostasis was achieved. The primary goal was feasibility. Secondary goals were volume of biopsy specimens and incidence of procedure-related tumor implantation. Results Bleeding volume during the procedure ranged from 0–50 g (median, 5 g; mean, 9 g) and stopped within 10 minutes in all patients. Pneumothorax occurred in two patients (11 %) and improved without chest tube insertion. Specimens could be obtained for the full needle length (2 cm) in 17 patients (94%), which enabled the chemosensitivity test to be performed in 14 patients (78%). Procedure-related tumor seeding was not apparent in any patient at a median of 16 months of follow-up after the procedure. Conclusions The present study showed that lung tumor biopsy with a 12-gauge needle through an outer sheath was feasible and enabled acquisition of specimens adequate for chemosensitivity testing without apparent procedure-related tumor seeding.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1051-0443
1535-7732