Determination of Hemolysis Thresholds by the Use of Data Loggers in Pneumatic Tube Systems

Pneumatic tube systems (PTSs) for the transport of blood samples are regaining popularity in medical centers after earlier reports that their use could introduce preanalytical distortions such as hemolysis and changes in blood gases. We drew duplicate blood samples from 30 volunteers. One sample was...

Full description

Saved in:
Bibliographic Details
Published inClinical chemistry (Baltimore, Md.) Vol. 57; no. 10; pp. 1390 - 1397
Main Authors STREICHERT, Thomas, OTTO, Benjamin, SCHNABEL, Claudia, NORDHOLT, Gerhard, HADDAD, Munif, MARIC, Mario, PETERSMANN, Astrid, JUNG, Roman, WAGENER, Christoph
Format Journal Article
LanguageEnglish
Published Washington, DC American Association for Clinical Chemistry 01.10.2011
Oxford University Press
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Pneumatic tube systems (PTSs) for the transport of blood samples are regaining popularity in medical centers after earlier reports that their use could introduce preanalytical distortions such as hemolysis and changes in blood gases. We drew duplicate blood samples from 30 volunteers. One sample was hand transported, and the other sample was transported through a PTS together with a mini-data logger that provided continuous measurements of temperature, humidity, pressure, and acceleration. After transport the samples were analyzed at the same time. We looked for possible relationships of the transport method and the parameters measured by the data loggers with differences in hematological parameters, standard clinical chemistry analyses, blood coagulation, erythrocyte sedimentation rate, and blood gas analysis. There were no significant differences in temperature, humidity, and pressure between the methods of transport, but we observed significant differences in 3-axis accelerations. The combined effect of these forces could be described by the right-tailed area under the vector sum acceleration distribution. Our data show that this area correlated with PTS speed and that PTS speed and the area under the curve exhibited a direct relation to the degree of hemolysis. Assessment of 3-axis acceleration by use of data loggers can be used to identify preanalytical deviations that result from the transportation of blood samples in PTSs. Our approach could be used for the evaluation and regular control of PTSs without the need for repeated blood drawing and laboratory analyses.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0009-9147
1530-8561
DOI:10.1373/clinchem.2011.167932