Assessment of Accuracy and Reliability in Preoperative Templating for Hip Resurfacing Arthroplasty

Abstract The current study investigated the accuracy and reliability of hip resurfacing component selection based on digital preoperative templating. Four surgeons made a template of preoperative radiographs on 2 occasions for acetabular and femoral components in 50 randomly selected hip resurfacing...

Full description

Saved in:
Bibliographic Details
Published inThe Journal of arthroplasty Vol. 25; no. 3; pp. 445 - 449
Main Authors Olsen, Michael, BSc, PhD, Gamble, Patrick, MD, FRCS(C), Chiu, Mark, MD, FRCS(C), Tumia, Nezar, MD, FRCSEd (Tr&Ortho), Boyle, Richard A., MD, FRACS, Schemitsch, Emil H., MD, FRCS(C)
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.04.2010
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Abstract The current study investigated the accuracy and reliability of hip resurfacing component selection based on digital preoperative templating. Four surgeons made a template of preoperative radiographs on 2 occasions for acetabular and femoral components in 50 randomly selected hip resurfacing patients. Component selection reliability was variable among surgeons ( κ = 0.16-0.73) and fair between surgeons ( κ = 0.23-0.32). The average percentage of agreement for the acetabular component was 47% (range, 32%-64%) and for the femoral component was 54% (range, 38%-70%). Surgeons tended to underestimate implant size if the correct implant was not chosen (acetabular, 29%; femoral, 32%). Selection of an undersized femoral component may lead to femoral neck notching or varus implant alignment. This study emphasizes the need for intraoperative verification of preoperative templating results to ensure optimal implant selection in hip resurfacing.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0883-5403
1532-8406
DOI:10.1016/j.arth.2009.01.022