Control Method of Failure for One Unit of Double Three-Phase-Wound Permanent Magnet Synchronous Machine Drive System Using Coupling of Dual Resolver

This paper presents a control method for the failure of one of the two units of a double three-phase-wound permanent magnet synchronous machine drive system without contact between these two units by estimating the state of the other unit based on magnetic coupling of a dual resolver. This paper pro...

Full description

Saved in:
Bibliographic Details
Published inIEEJ JOURNAL OF INDUSTRY APPLICATIONS Vol. 13; no. 5; pp. 587 - 593
Main Authors Mori, Tatsuya, Ikeda, Hiroko, Matsunaga, Toshihiro, Ikeda, Kenji, Kubo, Kenta
Format Journal Article
LanguageEnglish
Published The Institute of Electrical Engineers of Japan 01.09.2024
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:This paper presents a control method for the failure of one of the two units of a double three-phase-wound permanent magnet synchronous machine drive system without contact between these two units by estimating the state of the other unit based on magnetic coupling of a dual resolver. This paper proposes an another unit state estimation algorithm, in which the second unit extracts coupling signals from the output windings of the dual resolver. If the level of the extracted signals is smaller than threshold value, the first unit is determined to have failed. Experiments were conducted and the results showed the effectiveness of the proposed method.