Control Method of Failure for One Unit of Double Three-Phase-Wound Permanent Magnet Synchronous Machine Drive System Using Coupling of Dual Resolver
This paper presents a control method for the failure of one of the two units of a double three-phase-wound permanent magnet synchronous machine drive system without contact between these two units by estimating the state of the other unit based on magnetic coupling of a dual resolver. This paper pro...
Saved in:
Published in | IEEJ JOURNAL OF INDUSTRY APPLICATIONS Vol. 13; no. 5; pp. 587 - 593 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
The Institute of Electrical Engineers of Japan
01.09.2024
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | This paper presents a control method for the failure of one of the two units of a double three-phase-wound permanent magnet synchronous machine drive system without contact between these two units by estimating the state of the other unit based on magnetic coupling of a dual resolver. This paper proposes an another unit state estimation algorithm, in which the second unit extracts coupling signals from the output windings of the dual resolver. If the level of the extracted signals is smaller than threshold value, the first unit is determined to have failed. Experiments were conducted and the results showed the effectiveness of the proposed method. |
---|---|
ISSN: | 2187-1094 2187-1108 |
DOI: | 10.1541/ieejjia.23012082 |