Measurement of Fibrosis Marker Xylosyltransferase I Activity by HPLC Electrospray Ionization Tandem Mass Spectrometry

Xylosyltransferase I (XT-I), the key enzyme in the biosynthesis of glycosaminoglycan chains in proteoglycans, has increased activity in the blood serum of patients with connective tissue diseases. Therefore, the measurement of serum XT-I activity is useful to monitor disease activity in these patien...

Full description

Saved in:
Bibliographic Details
Published inClinical chemistry (Baltimore, Md.) Vol. 52; no. 12; pp. 2243 - 2249
Main Authors Kuhn, Joachim, Prante, Christian, Schon, Sylvia, Gotting, Christian, Kleesiek, Knut
Format Journal Article
LanguageEnglish
Published England Am Assoc Clin Chem 01.12.2006
Oxford University Press
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Xylosyltransferase I (XT-I), the key enzyme in the biosynthesis of glycosaminoglycan chains in proteoglycans, has increased activity in the blood serum of patients with connective tissue diseases. Therefore, the measurement of serum XT-I activity is useful to monitor disease activity in these patients. We developed an HPLC electrospray ionization tandem mass spectrometry method to assay XT-I activity in serum by use of a synthetic peptide (Bio-BIK-F) as the XT-I substrate. On the basis of XT-I-mediated transfer of D-xylose from UDP-D-xylose to the synthetic peptide to form Bio-BIK-F-Xyl, we determined XT-I activity in human serum samples. Multiple calibration curves for the analysis of Bio-BIK-F-Xyl exhibited consistent linearity and reproducibility in the range of 0.20-20 mg/L, corresponding to XT-I activity of 1.14-114 mU/L under assay conditions. The mean (SD, range) XT-I activity values in 30 blood donor sera were 18.4 (3.0, 8.7-24.8) mU/L. The limit of detection and lower limit of quantification were 8.5 microg/L (0.05 mU/L) and 163 microg/L Bio-BIK-F-Xyl (0.93 mU/L XT-I activity), respectively. Interassay imprecision (CV) was 5.4%-26.1% in the range of 0.64 to 129 mU/L, and mean recovery was 107% (range, 96%-129%). Method comparison with the radiochemical assay showed a moderate correlation (r = 0.79). The Passing-Bablok regression line was: radiochemical assay = 0.045 LC-MS/MS + 0.061 mU/L, S(y/x) = 0.186. This simple and robust LC-MS/MS assay permits the rapid and accurate determination of XT-I activity in human serum.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0009-9147
1530-8561
DOI:10.1373/clinchem.2006.071167