Tomosynthesis in the Diagnostic Setting: Changing Rates of BI-RADS Final Assessment over Time

Purpose To evaluate the effect of tomosynthesis in diagnostic mammography on the Breast Imaging Reporting and Data System (BI-RADS) final assessment categories over time. Materials and Methods This retrospective study was approved by the institutional review board. The authors reviewed all diagnosti...

Full description

Saved in:
Bibliographic Details
Published inRadiology Vol. 281; no. 1; pp. 54 - 61
Main Authors Raghu, Madhavi, Durand, Melissa A, Andrejeva, Liva, Goehler, Alexander, Michalski, Mark H, Geisel, Jaime L, Hooley, Regina J, Horvath, Laura J, Butler, Reni, Forman, Howard P, Philpotts, Liane E
Format Journal Article
LanguageEnglish
Published United States 01.10.2016
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Purpose To evaluate the effect of tomosynthesis in diagnostic mammography on the Breast Imaging Reporting and Data System (BI-RADS) final assessment categories over time. Materials and Methods This retrospective study was approved by the institutional review board. The authors reviewed all diagnostic mammograms obtained during a 12-month interval before (two-dimensional [2D] mammography [June 2, 2010, to June 1, 2011]) and for 3 consecutive years after (tomosynthesis year 1 [2012], tomosynthesis year 2 [2013], and tomosynthesis year 3 [2014]) the implementation of tomosynthesis. The requirement to obtain informed consent was waived. The rates of BI-RADS final assessment categories 1-5 were compared between the 2D and tomosynthesis groups. The positive predictive values after biopsy (PPV3) for BI-RADS category 4 and 5 cases were compared. The mammographic features (masses, architectural distortions, calcifications, focal asymmetries) of lesions categorized as probably benign (BI-RADS category 3) and those for which biopsy was recommended (BI-RADS category 4 or 5) were reviewed. The χ(2) test was used to compare the rates of BI-RADS final assessment categories 1-5 between the two groups, and multivariate logistic regression analysis was performed to compare all diagnostic studies categorized as BI-RADS 3-5. Results There was an increase in the percentage of cases reported as negative or benign (BI-RADS category 1 or 2) with tomosynthesis (58.7% with 2D mammography vs 75.8% with tomosynthesis at year 3, P < .0001). A reduction in the percentage of probably benign (BI-RADS category 3) final assessments also occurred (33.3% with 2D mammography vs 16.4% with tomosynthesis at year 3, P < .0001). Although the rates of BI-RADS 4 or 5 assessments did not change significantly with tomosynthesis (8.0% with 2D mammography vs 7.8% with tomosynthesis at year 3, P = .2), there was a significant increase in the PPV3 (29.6% vs 50%, respectively; P < .0001). These trends increased during the 3 years of tomosynthesis use. Conclusion Tomosynthesis in the diagnostic setting resulted in progressive shifts in the BI-RADS final assessment categories over time, with a significant increase in the proportion of studies classified as normal, a continued decrease in the rate of studies categorized as probably benign, and improved diagnostic confidence in biopsy recommendations. (©) RSNA, 2016.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0033-8419
1527-1315
DOI:10.1148/radiol.2016151999