Electrocardiogram-Assisted Blood Pressure Estimation

Accurate automatic noninvasive assessment of blood pressure (BP) presents a challenge due to conditions like arrhythmias, obesity, and postural changes that tend to obfuscate arterial amplitude pulsations sensed by the cuff. Researchers tried to overcome this challenge by analyzing oscillometric pul...

Full description

Saved in:
Bibliographic Details
Published inIEEE transactions on biomedical engineering Vol. 59; no. 3; pp. 608 - 618
Main Authors Ahmad, Saif, Chen, Silu, Soueidan, Karen, Batkin, Izmail, Bolic, Miodrag, Dajani, Hilmi, Groza, Voicu
Format Journal Article
LanguageEnglish
Published New York, NY IEEE 01.03.2012
Institute of Electrical and Electronics Engineers
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Accurate automatic noninvasive assessment of blood pressure (BP) presents a challenge due to conditions like arrhythmias, obesity, and postural changes that tend to obfuscate arterial amplitude pulsations sensed by the cuff. Researchers tried to overcome this challenge by analyzing oscillometric pulses with the aid of a higher fidelity signal-the electrocardiogram (ECG). Moreover, pulse transit time (PTT) was employed to provide an additional method for BP estimation. However, these methods were not fully developed, suitably integrated, or tested. To address these issues, we present a novel method whereby ECG-assisted oscillometric and PTT (measured between ECG R-peaks and maximum slope of arterial pulse peaks) analyses are seamlessly integrated into the oscillometric BP measurement paradigm. The method bolsters oscillometric analysis (amplitude modulation) with more reliable ECG R-peaks provides a complementary measure with PTT analysis (temporal modulation) and fuses this information for robust BP estimation. We have integrated this technology into a prototype that comprises a BP cuff with an embedded conductive fabric ECG electrode, associated hardware, and algorithms. A pilot study has been undertaken on ten healthy subjects (150 recordings) to validate the performance of our prototype against United States Food and Drug Administration approved Omron oscillometric monitor (HEM-790IT). Our prototype achieves mean absolute difference of less than 5 mmHg and grade A as per the British Hypertension Society protocol for estimating BP, with the reference Omron monitor.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Article-2
ObjectType-Conference-1
ObjectType-Feature-3
SourceType-Conference Papers & Proceedings-2
ISSN:0018-9294
1558-2531
DOI:10.1109/TBME.2011.2180019