Aortic Stent-Graft Explantation in a Kidney Transplant Recipient

AAA repair in renal transplant recipients has generated a variety of methods of managing the allograft. Endovascular techniques have been successfully employed in this patient population. Due to inherent limitations of present endovascular methods, occasional stent-graft excision must be performed....

Full description

Saved in:
Bibliographic Details
Published inAnnals of vascular surgery Vol. 23; no. 4; pp. 535.e21 - 535.e26
Main Authors Hughes, John D, Leon, Luis R, Goshima, Kaoru R
Format Journal Article
LanguageEnglish
Published Netherlands Elsevier Inc 01.07.2009
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:AAA repair in renal transplant recipients has generated a variety of methods of managing the allograft. Endovascular techniques have been successfully employed in this patient population. Due to inherent limitations of present endovascular methods, occasional stent-graft excision must be performed. We present a case of aortic stent-graft excision in a renal transplant recipient using a pump-oxygenator to maintain allograft perfusion.
Bibliography:ObjectType-Case Study-2
SourceType-Scholarly Journals-1
ObjectType-Feature-4
content type line 23
ObjectType-Report-1
ObjectType-Article-3
ISSN:0890-5096
1615-5947
DOI:10.1016/j.avsg.2008.08.017