Interobserver and intraobserver variability of glenoid track measurements

Background A method of assessing combined glenoid and humeral bone loss in traumatic shoulder instability with an associated treatment protocol was recently published. The aim of this study was to investigate its reliability and reproducibility. Methods Seventy-one patients with unilateral anteroinf...

Full description

Saved in:
Bibliographic Details
Published inJournal of shoulder and elbow surgery Vol. 26; no. 4; pp. 573 - 579
Main Authors Schneider, Adrian K., FMH(Orth), MD, Hoy, Gregory A., MBBS, Dip Anat., FRACS(Orth), Ek, Eugene T., MBBS(Hons), PhD, FRACS(Orth), Rotstein, Andrew H., MBBS, FRANZCR, Tate, Julie, BSc(Hons), PgCert(CT), Taylor, David McD, MBBS, MD, MPH, DRCOG, FACEM, Evans, Matthew C., MBBS, FRACS(Orth)
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.04.2017
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background A method of assessing combined glenoid and humeral bone loss in traumatic shoulder instability with an associated treatment protocol was recently published. The aim of this study was to investigate its reliability and reproducibility. Methods Seventy-one patients with unilateral anteroinferior shoulder instability underwent computed tomography scans, from which 3-dimensional images were derived. En face views of both glenoid fossae and with 3 views of the humeral head were provided to 4 assessors to determine interobserver reliability. From these measurements, the shoulder was assigned a treatment classification. Two observers repeated their assessments 1 month later to determine intraobserver reliability. For each measurement, the mean coefficient of variability was calculated. Results Assessment of glenoid bone loss showed good interobserver (4 observers agreeing in 90.1% of cases) and also good intraobserver agreement (94% and 96%). There was a poor level of interobserver reliability regarding the on-track or off-track classification (72%). Intraobserver reliability for this measurement was less variable (90% and 80%). There was a poor level of agreement between observers (65%) regarding treatment classification. The coefficient of variability for the Hill-Sachs lesion measured 19.2%, indicating a high level of variability for this measurement compared with <4% for all other measures. Conclusion Linear bone loss on the glenoid can be measured reliably and reproducibly; however, evaluation of Hill-Sachs lesions demonstrates a high level of variability, and poor interobserver reliability.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1058-2746
1532-6500
DOI:10.1016/j.jse.2016.09.058