Electrochemiluminescence immunosensor for highly sensitive detection of 8-hydroxy-2′-deoxyguanosine based on carbon quantum dot coated Au/SiO2 core–shell nanoparticles
An electrochemiluminescence (ECL) immunosensor using Pt electrode modified with carbon quantum dot (CQDs) coated Au/SiO2 core–shell nanoparticles was proposed for sensitive detection of 8-hydroxy-2′-deoxyguanosine (8-OHdG) in this work. Rabbit anti-8-OHdG antibody was covalently bound to CQDs on the...
Saved in:
Published in | Talanta (Oxford) Vol. 131; pp. 379 - 385 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
Netherlands
Elsevier B.V
01.01.2015
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | An electrochemiluminescence (ECL) immunosensor using Pt electrode modified with carbon quantum dot (CQDs) coated Au/SiO2 core–shell nanoparticles was proposed for sensitive detection of 8-hydroxy-2′-deoxyguanosine (8-OHdG) in this work. Rabbit anti-8-OHdG antibody was covalently bound to CQDs on the surface of Au/SiO2 core–shell nanoparticles. Through signal amplification of Au/SiO2 core–shell nanoparticles, 8-fold enhancement of the ECL signals was achieved. Under optimal conditions, a good linear range from 0.2 to 200ngmL−1 with a low detection limit of 0.085ngmL−1 (S/N=3) for 8-OHdG detection was obtained. Interfering substances tests showed that the corresponding ECL intensity (ΔECL) of 8-OHdG is 8–18 times higher than that of guanine, uric acid (UA) and ascorbic acid, demonstrating its good selectivity for 8-OHdG detection. The ECL immnuosensor exhibits long-term stability with a relative standard deviation (RSD) of 8.5% even after 16 cycles of continuous potential scans. The result of analytical detection of 8-OHdG in real samples was satisfactory. The proposed ECL immnuosensor shows good performance with high sensitivity, specificity, repeatability, stability and provided a powerful tool for 8-OHdG monitoring in clinical samples.
A rapid, and highly sensitive electrochemiluminescence immunosensor based on carbon quantum dot coated Au/SiO2 core–shell nanoparticles is presented for 8-hydroxy-2′-deoxyguanosine detection. [Display omitted]
●An ECL sensor was constructed by Au/SiO2/CQDs NPs modified Pt electrode.●This ECL sensor was used for sensitive detection of 8-OHdG.●The ECL intensity of Pt/Au/SiO2/CQDs was 8 times as high as that of Pt/CQDs.●The ECL sensor displayed a high sensitivity, excellent selectivity. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0039-9140 1873-3573 |
DOI: | 10.1016/j.talanta.2014.08.024 |