A Safe Technique to Ensure Not to Unload a Suture Anchor: Suture Dyeing

Suture anchors are frequently used in shoulder arthroscopy. After suture anchors are inserted into bone, the suture transfer between portals should be performed carefully. Sometimes, as a result of the transfer of the wrong suture limb, the suture anchor may be unloaded. The suture dyeing technique...

Full description

Saved in:
Bibliographic Details
Published inArthroscopy techniques (Amsterdam) Vol. 12; no. 4; pp. e545 - e547
Main Authors Öçgüder, Durmuş Ali, Sarikaya, Baran, Eren, Semih, Bozkurt, İbrahim
Format Journal Article
LanguageEnglish
Published Netherlands Elsevier Inc 01.04.2023
Elsevier
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Suture anchors are frequently used in shoulder arthroscopy. After suture anchors are inserted into bone, the suture transfer between portals should be performed carefully. Sometimes, as a result of the transfer of the wrong suture limb, the suture anchor may be unloaded. The suture dyeing technique provides secure suture retrieval between portals. [Display omitted]