Stent-Graft Deployment to Treat a Perigraft Seroma Formed after Descending Thoracic Aortic Surgery
Purpose: To report a case of stent-graft implantation for a perigraft seroma that formed after descending thoracic aortic surgery. Case Report: A 70-year-old woman presented with a perigraft seroma after a descending thoracic aortic surgery 10 years ago in which a polytetrafluoroethylene graft was u...
Saved in:
Published in | Journal of endovascular therapy Vol. 14; no. 6; pp. 813 - 815 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
Los Angeles, CA
SAGE Publications
01.12.2007
Allen Press Inc |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Purpose:
To report a case of stent-graft implantation for a perigraft seroma that formed after descending thoracic aortic surgery.
Case Report:
A 70-year-old woman presented with a perigraft seroma after a descending thoracic aortic surgery 10 years ago in which a polytetrafluoroethylene graft was used. Chest radiography and computed tomography confirmed the presence of a large perigraft seroma. The previous graft was covered with a stent-graft to decrease graft porosity. At 1 year, postoperative examinations revealed a decrease in the size of the perigraft seroma.
Conclusion:
Stent-graft implantation could prove useful in cases of perigraft seromas where additional conventional surgery may pose difficulties. |
---|---|
Bibliography: | ObjectType-Case Study-2 SourceType-Scholarly Journals-1 ObjectType-Feature-4 content type line 23 ObjectType-Report-1 ObjectType-Article-3 |
ISSN: | 1526-6028 1545-1550 |
DOI: | 10.1583/06-2037.1 |