Cavitation Surge in a Small Model Test Facility simulating a Hydraulic Power Plant
Model tests and CFD were carried out to find out the cause of cavitation surge in hydraulic power plants. In experiments the cavitation surge was observed at flow rates higher and lower than the swirl free flow rate, both with and without a surge tank placed just upstream of the inlet volute. The su...
Saved in:
Published in | International journal of fluid machinery and systems Vol. 5; no. 4; pp. 152 - 160 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
한국유체기계학회
2012
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Model tests and CFD were carried out to find out the cause of cavitation surge in hydraulic power plants. In experiments the cavitation surge was observed at flow rates higher and lower than the swirl free flow rate, both with and without a surge tank placed just upstream of the inlet volute. The surge frequency at smaller flow rate was much smaller than the swirl mode frequency caused by the whirl of vortex rope. An unsteady CFD was carried out with two boundary conditions: (1) the flow rate is fixed to be constant at the volute inlet, (2) the total pressure is kept constant at the volute inlet, corresponding to the experiments without/with the surge tank. The surge was observed with both boundary conditions at both higher and lower flow rates. Discussions as to the cause of the surge are made based on additional tests with an orifice at the diffuser exit, and with the diffuser replaced with a straight pipe. KCI Citation Count: 1 |
---|---|
Bibliography: | G704-SER000002597.2012.5.4.001 https://www.jstage.jst.go.jp/article/ijfms/5/4/5_152/_article |
ISSN: | 1882-9554 1882-9554 |
DOI: | 10.5293/IJFMS.2012.5.4.152 |