COST-EFFECTIVENESS OF CONTINUOUS-FLOW LEFT VENTRICULAR ASSIST DEVICES

Objectives: Mechanical circulatory support through left ventricular assist devices (LVADs) improves survival and quality of life for patients with end-stage heart failure who are ineligible for cardiac transplantation. Our aim was to calculate the cost-effectiveness of continuous-flow LVADs. Methods...

Full description

Saved in:
Bibliographic Details
Published inInternational journal of technology assessment in health care Vol. 29; no. 3; pp. 254 - 260
Main Authors Neyt, Mattias, Van den Bruel, Ann, Smit, Yolba, De Jonge, Nicolaas, Erasmus, Michiel, Van Dijk, Diederik, Vlayen, Joan
Format Journal Article
LanguageEnglish
Published New York, USA Cambridge University Press 01.07.2013
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objectives: Mechanical circulatory support through left ventricular assist devices (LVADs) improves survival and quality of life for patients with end-stage heart failure who are ineligible for cardiac transplantation. Our aim was to calculate the cost-effectiveness of continuous-flow LVADs. Methods: A cost-utility analysis from a societal perspective was performed. A lifetime Markov model was set up in which continuous-flow LVAD was compared with optimal medical therapy (OMT). The treatment effect was modeled indirectly combining the results of the REMATCH trial comparing OMT with a pulsatile-flow LVAD and the HeartMate II Destination Therapy Trial comparing a pulsatile-flow LVAD with a continuous-flow LVAD. Cost data were based on real-world financial data of sixty-nine patients with a HeartMate II implantation from the University Medical Centre Utrecht (the Netherlands). One-way and probabilistic sensitivity analyses were performed. Results: Comparing the continuous-flow HeartMate II with OMT, 3.23 (95 percent confidence interval [CI], 2.18–4.49) life-years were gained (LYG) or 2.83 (95 percent CI, 1.91–3.90) quality-adjusted life-years (QALYs). The cost of an LVAD implant was approximately €126,000, of which the device itself represented the largest cost, being €70,000. Total incremental costs amounted to €299,100 (95 percent CI, 190,500–521,000). This resulted in an incremental cost-effectiveness ratio of €94,100 (95 percent CI, 59,100–160,100) per LYG or €107,600 (95 percent CI, 66,700–181,100) per QALY. Sensitivity analyses showed these results were robust. Conclusions: Although LVAD destination therapy improves survival and quality of life, it remains a relatively expensive intervention which renders the reimbursement of this therapy questionable.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Article-2
ObjectType-Feature-1
ISSN:0266-4623
1471-6348
DOI:10.1017/S0266462313000238