Optic chiasmatic potential by endoscopically implanted skull base microinvasive biosensor: a brain-machine interface approach for anterior visual pathway assessment

Visually evoked potential (VEP) is widely used to detect optic neuropathy in basic research and clinical practice. Traditionally, VEP is recorded non-invasively from the surface of the skull over the visual cortex. However, its trace amplitude is highly variable, largely due to intracranial modulati...

Full description

Saved in:
Bibliographic Details
Published inTheranostics Vol. 12; no. 7; pp. 3273 - 3287
Main Authors Zhang, Yikui, Lu, Shengjian, Huang, Shenghai, Yu, Zhonghao, Xia, Tian, Li, Mengyun, Yang, Chen, Mao, Yiyang, Xu, Boyue, Wang, Lixu, Xu, Lei, Shi, Jieliang, Zhu, Xingfang, Zhu, Senmiao, Zhang, Si, Qian, Haohua, Hu, Yang, Li, Wei, Tu, Yunhai, Wu, Wencan
Format Journal Article
LanguageEnglish
Published Australia Ivyspring International Publisher Pty Ltd 01.01.2022
Ivyspring International Publisher
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Visually evoked potential (VEP) is widely used to detect optic neuropathy in basic research and clinical practice. Traditionally, VEP is recorded non-invasively from the surface of the skull over the visual cortex. However, its trace amplitude is highly variable, largely due to intracranial modulation and artifacts. Therefore, a safe test with a strong and stable signal is highly desirable to assess optic nerve function, particularly in neurosurgical settings and animal experiments. Minimally invasive trans-sphenoidal endoscopic recording of optic chiasmatic potential (OCP) was carried out with a titanium screw implanted onto the sphenoid bone beneath the optic chiasm in the goat, whose sphenoidal anatomy is more human-like than non-human primates. The implantation procedure was swift (within 30 min) and did not cause any detectable abnormality in fetching/moving behaviors, skull CT scans and ophthalmic tests after surgery. Compared with traditional VEP, the amplitude of OCP was 5-10 times stronger, more sensitive to weak light stimulus and its subtle changes, and was more repeatable, even under extremely low general anesthesia. Moreover, the OCP signal relied on ipsilateral light stimulation, and was abolished immediately after complete optic nerve (ON) transection. Through proof-of-concept experiments, we demonstrated several potential applications of the OCP device: (1) real-time detector of ON function, (2) detector of region-biased retinal sensitivity, and (3) therapeutic electrical stimulator for the optic nerve with low and thus safe excitation threshold. OCP developed in this study will be valuable for both vision research and clinical practice. This study also provides a safe endoscopic approach to implant skull base brain-machine interface, and a feasible testbed (goat) for evaluating safety and efficacy of skull base brain-machine interface.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
These authors contributed equally to this work.
Competing Interests: The authors have declared that no competing interest exists.
ISSN:1838-7640
1838-7640
DOI:10.7150/thno.71164