Role of locking plates in treatment of difficult ununited fractures: a clinical study

Objective: To present our experience in treatment of difficult ununited long bone fractures with locking plate. Methods: Retrospective evaluation of locking plate fixation in 10 difficult nonunions of long bone fractures was done. Fixation was done with locking plate for femoral shaft fracture (3 pa...

Full description

Saved in:
Bibliographic Details
Published inChinese journal of traumatology Vol. 16; no. 1; pp. 22 - 26
Main Authors Kumar, Ashok, Gupta, Himanshu, Yadav, Chandra Shekhar, Khan, Shah Alam, Rastogi, Shishir
Format Journal Article
LanguageEnglish
Published China Elsevier B.V 01.02.2013
Dubai Bone & Joint Center, Mohammed Bin Rashid Al Makotoum Academic Medical Center, Dubai Health Carecity, Dubai 118855, UAE%Department of Orthopaedics, All India Institute of Medical Sciences, Ansari Nagar, New Delhi 110029, India
Elsevier
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objective: To present our experience in treatment of difficult ununited long bone fractures with locking plate. Methods: Retrospective evaluation of locking plate fixation in 10 difficult nonunions of long bone fractures was done. Fixation was done with locking plate for femoral shaft fracture (3 patients), supracondylar fracture of femur (gap nonunion), fracture of clavicle, fracture of both forearm bones (radius and ulna) fracture of ulna, fracture of shaft of humerus, fracture of tibial diaphysis and supracondylar frac- ture of humerus (one patient each). Five fractures had more than one previous failed internal fixation. One patient had infected nonunion which was managed by debridement with cast immobilization followed by fixation with locking plate at six weeks. Seven fractures were atrophic, two were oligotrophic, and one was hypertrophic. Fibular autograft was used in 2 cases and iliac crest cancellous bone graft used in all the patients. Results: Minimum follow-up was 6 months (range, 6 months to 2.5 years). Average time for union was 3.4 months (range 2.5 to 6 months). None of the patients had plate- related complications or postoperative wound infections. Conclusion: Along with achieving stability with locking compression plate, meticulous soft tissue dissection, acceptable reduction, good fixation technique and bone grafting can help achieve union in difficult nonunion cases. Though locking plate does not by itself ensure bony union, we have found it to be another useful addition to our armamentarium for treating difficult fracture nonunions.
Bibliography:Objective: To present our experience in treatment of difficult ununited long bone fractures with locking plate. Methods: Retrospective evaluation of locking plate fixation in 10 difficult nonunions of long bone fractures was done. Fixation was done with locking plate for femoral shaft fracture (3 patients), supracondylar fracture of femur (gap nonunion), fracture of clavicle, fracture of both forearm bones (radius and ulna) fracture of ulna, fracture of shaft of humerus, fracture of tibial diaphysis and supracondylar frac- ture of humerus (one patient each). Five fractures had more than one previous failed internal fixation. One patient had infected nonunion which was managed by debridement with cast immobilization followed by fixation with locking plate at six weeks. Seven fractures were atrophic, two were oligotrophic, and one was hypertrophic. Fibular autograft was used in 2 cases and iliac crest cancellous bone graft used in all the patients. Results: Minimum follow-up was 6 months (range, 6 months to 2.5 years). Average time for union was 3.4 months (range 2.5 to 6 months). None of the patients had plate- related complications or postoperative wound infections. Conclusion: Along with achieving stability with locking compression plate, meticulous soft tissue dissection, acceptable reduction, good fixation technique and bone grafting can help achieve union in difficult nonunion cases. Though locking plate does not by itself ensure bony union, we have found it to be another useful addition to our armamentarium for treating difficult fracture nonunions.
Fractures, bone; Fractures, .ununited; Bone plates; Orthopedic fixation devices