Optimizing reverse shoulder arthroplasty component position in the setting of advanced arthritis with posterior glenoid erosion: a computer-enhanced range of motion analysis

Our study purpose was to determine the optimal glenoid and humeral reverse shoulder arthroplasty (RSA) component design and position in osteoarthritic shoulders with severe glenoid retroversion deformities. Computed tomography scans from 10 subjects were analyzed with advanced software including RSA...

Full description

Saved in:
Bibliographic Details
Published inJournal of shoulder and elbow surgery Vol. 27; no. 2; pp. 339 - 349
Main Authors Keener, Jay D., Patterson, Brendan M., Orvets, Nathan, Aleem, Alexander W., Chamberlain, Aaron M.
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.02.2018
Subjects
Online AccessGet full text
ISSN1058-2746
1532-6500
1532-6500
DOI10.1016/j.jse.2017.09.011

Cover

Loading…
More Information
Summary:Our study purpose was to determine the optimal glenoid and humeral reverse shoulder arthroplasty (RSA) component design and position in osteoarthritic shoulders with severe glenoid retroversion deformities. Computed tomography scans from 10 subjects were analyzed with advanced software including RSA range of motion (ROM) analysis. Variables included glenoid component retroversion of 0°, 5°, 10°, 15°, and 20° and baseplate lateralization of 0, 5, and 10 mm. Humeral variables included 135°, 145°, and 155° angle of inclination (AOI) combined with variable humeral offset. Glenoid component lateralization had the greatest influence on ROM. In comparing each ROM direction among all lateralization options independently, there were significantly greater adduction, abduction, external rotation, extension, and flexion motions with progressively greater lateralization. Internal rotation motion was greater at 10 mm only. In analyzing the effects of glenoid version independently, no differences in adduction or abduction ROM were seen. With greater retroversion, decreased external rotation and extension motion was noted; however, greater internal rotation and flexion motion was seen with the exception of flexion at 10 mm of lateralization. For adduction, external rotation, and extension, a more valgus AOI resulted in less ROM at each progressively greater AOI independent of humeral lateralization. Internal rotation and flexion motions were greater with a more varus AOI but not significant between each inclination angle. Abduction ROM was maximized with a more valgus AOI. Humeral lateralization had no effect on ROM. In the setting of RSA for advanced glenoid osteoarthritic deformities, optimal ROM is achieved with 10-mm baseplate lateralization and neutral to 5° of retroversion mated to a humeral implant with a varus (135°) inclination angle.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1058-2746
1532-6500
1532-6500
DOI:10.1016/j.jse.2017.09.011