Heat transfer rate of direct-contact condensation on baffle trays

The paper deals with the experimentally obtained results of the direct-contact condensation of steam in contact with water in cascade column. Baffle trays were used to obtain contact between water and steam in DN 300 column at atmospheric pressure. Testing of Chernobilski equation showed poor correl...

Full description

Saved in:
Bibliographic Details
Published inInternational journal of heat and mass transfer Vol. 51; no. 25; pp. 5772 - 5776
Main Authors GENIT, Srbislav B, JACIMOVIC, Branislav M, VLADIC, Ljubisa A
Format Journal Article
LanguageEnglish
Published Kidlington Elsevier Ltd 01.12.2008
Elsevier
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The paper deals with the experimentally obtained results of the direct-contact condensation of steam in contact with water in cascade column. Baffle trays were used to obtain contact between water and steam in DN 300 column at atmospheric pressure. Testing of Chernobilski equation showed poor correlation compared to the experimental results so we have found the following form of heat transfer rate Nu = 5.8 · 10 - 6 · Re 5 / 3 · Pr 1 / 3 · Fr - 2 / 3 which could be recommended for heat transfer calculations for this kind of apparatuses.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:0017-9310
1879-2189
DOI:10.1016/j.ijheatmasstransfer.2008.05.017