Effect of Respirator Resistance on Tolerant Capacity during Graded Load Exercise

Respirator breathing resistance impacts performance of wearers during constant work load. However, it is less clear as to how breathing resistance affects the tolerant capacity of users during graded work load. The present study investigated the tolerant capacity of 8 individuals during incremental...

Full description

Saved in:
Bibliographic Details
Published inJournal of Huazhong University of Science and Technology. Medical sciences Vol. 32; no. 3; pp. 434 - 437
Main Author 邱曼 王生
Format Journal Article
LanguageEnglish
Published Heidelberg Huazhong University of Science and Technology 01.06.2012
Subjects
Online AccessGet full text
ISSN1672-0733
1993-1352
DOI10.1007/s11596-012-0075-x

Cover

Loading…
More Information
Summary:Respirator breathing resistance impacts performance of wearers during constant work load. However, it is less clear as to how breathing resistance affects the tolerant capacity of users during graded work load. The present study investigated the tolerant capacity of 8 individuals during incremental work load. The 8 subjects were required to wear two matched respirators (respirators Ⅰ and Ⅱ which were designed to have different breathing resistances and the same dead space) respectively on separate days and then work to end points. Minute ventilation (VE), breathing frequency (BF), oxygen consumption (VO2) and heart rate (HR) were recorded during exercise, while tolerant time, response time and breathing discomfort were measured at the end of each test trial. The test variables were com-pared between the two respirators by using matched-pairs t-test. The results showed that the tolerant time was significantly reduced for the respiratorⅠwith higher level of breathing resistance when compared with its counterpart with lower breathing resistance (respirator Ⅱ) (P〈0.05). The same changes occurred for response time. Results also showed a significant increase in VE and BF for respirator Ⅰwearers when the work load was above 125 W. The O2 consumption was similar under the two breathing resistance conditions. These findings suggested that the respiratory resistance caused by self-contained breathing apparatus (SCBA) has an impact on the tolerant capacity of users.
Bibliography:self-contained breathing apparatus breathing resistance respirator tolerant time
42-1679/R
Man QIU, Sheng WANG( School of Public Health, PeKing University, Beijing 100191, China)
Respirator breathing resistance impacts performance of wearers during constant work load. However, it is less clear as to how breathing resistance affects the tolerant capacity of users during graded work load. The present study investigated the tolerant capacity of 8 individuals during incremental work load. The 8 subjects were required to wear two matched respirators (respirators Ⅰ and Ⅱ which were designed to have different breathing resistances and the same dead space) respectively on separate days and then work to end points. Minute ventilation (VE), breathing frequency (BF), oxygen consumption (VO2) and heart rate (HR) were recorded during exercise, while tolerant time, response time and breathing discomfort were measured at the end of each test trial. The test variables were com-pared between the two respirators by using matched-pairs t-test. The results showed that the tolerant time was significantly reduced for the respiratorⅠwith higher level of breathing resistance when compared with its counterpart with lower breathing resistance (respirator Ⅱ) (P〈0.05). The same changes occurred for response time. Results also showed a significant increase in VE and BF for respirator Ⅰwearers when the work load was above 125 W. The O2 consumption was similar under the two breathing resistance conditions. These findings suggested that the respiratory resistance caused by self-contained breathing apparatus (SCBA) has an impact on the tolerant capacity of users.
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1672-0733
1993-1352
DOI:10.1007/s11596-012-0075-x