Optical Biometry and IOL Calculation in a Commercially Available Optical Coherence Tomography Device and Comparison With Pentacam AXL

Optical devices are the gold standard for ocular biometry; however, they are unable to obtain high-quality optical coherence tomography (OCT) images. The current study aimed to evaluate ocular measurements and intraocular lens (IOL) calculation used in an anterior/posterior segment OCT device and to...

Full description

Saved in:
Bibliographic Details
Published inAmerican journal of ophthalmology Vol. 246; pp. 236 - 241
Main Authors Kanclerz, Piotr, Hoffer, Kenneth J., Bazylczyk, Natasza, Wang, Xiaogang, Savini, Giacomo
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.02.2023
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Optical devices are the gold standard for ocular biometry; however, they are unable to obtain high-quality optical coherence tomography (OCT) images. The current study aimed to evaluate ocular measurements and intraocular lens (IOL) calculation used in an anterior/posterior segment OCT device and to compare the results with those of a validated biometer. Prospective evaluation of a diagnostic tool. This study enrolled healthy subjects at the Hygeia Clinic, Gdańsk, Poland, between October 2021 and November 2021. All individuals had ocular biometry measured with a validated biometer (Pentacam AXL) and with a new module of an anterior/posterior segment OCT device (Revo 80, Optopol Technologies). All IOL calculations were performed for the right eye with keratometric values from the Pentacam for one IOL: the Alcon AcrySof IQ SN60WF, with plano target setting. The mean age of the 144 participants was 25.23 ± 7.15 years. The axial length measured with Revo was longer than with Pentacam AXL (24.08 ± 1.13 vs 23.98 ± 1.13; P < .0001), a 0.10 ± 0.04 mm difference. This translated into a significantly lower IOL power to achieve emmetropia for all formulas (–0.34 ± 0.15, –0.32 ± 0.13, –0.34 ± 0.19, and –0.30 ± 0.15 for the Hoffer Q, Holladay I, Haigis, and SRK/T formulas, respectively). The study showed high agreement between the devices: nearly 90% of eyes were within ±0.50 diopters for all of the analyzed formulas (r > 0.99). The present study demonstrates that the results of IOL calculation with the OCT biometer have a very strong correlation with those obtained with the Pentacam AXL; however, axial length measurements and calculated IOL power cannot be considered interchangeable.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0002-9394
1879-1891
1879-1891
DOI:10.1016/j.ajo.2022.09.022