Quantification of Wave Reflection in the Human Aorta From Pressure Alone: A Proof of Principle

Wave reflections affect the proximal aortic pressure and flow waves and play a role in systolic hypertension. A measure of wave reflection, receiving much attention, is the augmentation index (AI), the ratio of the secondary rise in pressure and pulse pressure. AI can be limiting, because it depends...

Full description

Saved in:
Bibliographic Details
Published inHypertension (Dallas, Tex. 1979) Vol. 48; no. 4; pp. 595 - 601
Main Authors Westerhof, Berend E., Guelen, Ilja, Westerhof, Nico, Karemaker, John M., Avolio, Alberto
Format Journal Article
LanguageEnglish
Published United States American Heart Association, Inc 01.10.2006
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Wave reflections affect the proximal aortic pressure and flow waves and play a role in systolic hypertension. A measure of wave reflection, receiving much attention, is the augmentation index (AI), the ratio of the secondary rise in pressure and pulse pressure. AI can be limiting, because it depends not only on the magnitude of wave reflection but also on wave shapes and timing of incident and reflected waves. More accurate measures are obtainable after separation of pressure in its forward (Pf) and reflected (Pb) components. However, this calculation requires measurement of aortic flow. We explore the possibility of replacing the unknown flow by a triangular wave, with duration equal to ejection time, and peak flow at the inflection point of pressure (F) and, for a second analysis, at 30% of ejection time (F). Wave form analysis gave forward and backward pressure waves. Reflection magnitude (RM) and reflection index (RI) were defined as RM=Pb/Pf and RI=Pb/(Pf+Pb), respectively. Healthy subjects, including interventions such as exercise and Valsalva maneuvers, and patients with ischemic heart disease and failure were analyzed. RMs and RIs using F and F were compared with those using measured flow (F). Pressure and flow were recorded with high fidelity pressure and velocity sensors. Relations areRM=0.82RM+0.06 (R=0.79; n=24), RM=0.79RM+0.08 (R=0.85; n=29) and RI=0.89RI+0.02 (R=0.81; n=24), RI=0.83RI+0.05 (R=0.88; n=29). We suggest that wave reflection can be derived from uncalibrated aortic pressure alone, even when no clear inflection point is distinguishable and AI cannot be obtained. Epidemiological studies should establish its clinical value.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0194-911X
1524-4563
1524-4563
DOI:10.1161/01.HYP.0000238330.08894.17