A retrospective analysis of the accuracy of T2-weighted images and dynamic gadolinium-enhanced sequences in the detection and characterization of focal hepatic lesions

The aim of this study was to determine the relative ability of T2‐weighted and dynamic gadolinium‐enhanced T1‐weighted gradient‐echo sequences to detect and characterize focal hepatic lesions. We retrospectively studied 37 patients with proven focal hepatic lesions using the following sequences: a T...

Full description

Saved in:
Bibliographic Details
Published inJournal of magnetic resonance imaging Vol. 9; no. 2; pp. 266 - 273
Main Authors Pawluk, Randolph S., Tummala, Satish, Brown, Jeffrey J., Borrello, Joseph A.
Format Journal Article
LanguageEnglish
Published New York John Wiley & Sons, Inc 01.02.1999
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The aim of this study was to determine the relative ability of T2‐weighted and dynamic gadolinium‐enhanced T1‐weighted gradient‐echo sequences to detect and characterize focal hepatic lesions. We retrospectively studied 37 patients with proven focal hepatic lesions using the following sequences: a T1‐weighted spin‐echo sequence (T1), a T2‐weighted sequence (T2), and a series of breath‐hold dynamic gadolinium‐enhanced T1‐weighted gradient‐echo sequences (Gd). Two observers were asked to determine retrospectively the number and type of focal hepatic lesions present using images from three combinations of sequences (T1+T2, T1+Gd, T1+T2+Gd). Proof of the number and diagnosis of focal lesions in each patient was established using a consensus read. Both readers detected more focal lesions when both the T2‐weighted sequences and the gadolinium‐enhanced sequences were available than on either sequence alone, although this improvement reached statistical significance (P < 0.05) only for one of the readers. There was no significant difference (P < 0.05) in the ability to characterize lesions between any of the sets of sequences. The combination of dynamic gadolinium‐enhanced images and T2‐weighted images was shown to assess focal hepatic lesions better than either of these sequences alone.J. Magn. Reson. Imaging 1999;9:266–273. © 1999 Wiley‐Liss, Inc.
Bibliography:istex:F0658707CE1283D823BB4CD5CF8E308CD2914234
ark:/67375/WNG-Z04CNZ48-K
ArticleID:JMRI17
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1053-1807
1522-2586
DOI:10.1002/(SICI)1522-2586(199902)9:2<266::AID-JMRI17>3.0.CO;2-7