Infrared image‐based multi‐point temperature monitoring for ultra‐high‐voltage direct current wall bushings subject to insulation shed interference
Ultra‐high‐voltage direct current wall bushings are critical components in direct current transmission systems. Temperature variations and abnormal distributions can signal potential equipment failures that threaten system stability. Therefore, monitoring these critical multi‐point temperature varia...
Saved in:
Published in | High voltage Vol. 10; no. 2; pp. 411 - 418 |
---|---|
Main Authors | , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
Beijing
John Wiley & Sons, Inc
01.04.2025
Wiley |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Ultra‐high‐voltage direct current wall bushings are critical components in direct current transmission systems. Temperature variations and abnormal distributions can signal potential equipment failures that threaten system stability. Therefore, monitoring these critical multi‐point temperature variations is essential. However, the unique design of the bushings, featuring insulation sheds of periodic shape, distorts infrared temperature measurements by introducing interference points. These interference points, dependent on the measurement's angle and distance, appear irregularly in infrared images, severely impacting the accuracy of multi‐point temperature distribution assessments. To address this challenge, an anomaly detection method is proposed that adaptively identifies interference points. The method identifies interference points by comparing pixels and uses a voting mechanism to improve identification accuracy. Compared with traditional methods, this approach presents two main advantages: adaptive identification capability, which enables it to recognise interference points and adapt to changing conditions, and unsupervised learning, which enables it to work effectively without requiring manually labelled data. Experimental tests on 161 bushing infrared images demonstrate the effectiveness of the method, achieving a 100% success rate in identifying localised overheating issues. The method has been integrated into high‐voltage direct current transmission anomaly systems and can be used to monitor critical equipment, enhancing system reliability and safety. |
---|---|
Bibliography: | Associate Editor Jin Li ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 |
ISSN: | 2397-7264 2096-9813 2397-7264 |
DOI: | 10.1049/hve2.70007 |