Infrared image‐based multi‐point temperature monitoring for ultra‐high‐voltage direct current wall bushings subject to insulation shed interference

Ultra‐high‐voltage direct current wall bushings are critical components in direct current transmission systems. Temperature variations and abnormal distributions can signal potential equipment failures that threaten system stability. Therefore, monitoring these critical multi‐point temperature varia...

Full description

Saved in:
Bibliographic Details
Published inHigh voltage Vol. 10; no. 2; pp. 411 - 418
Main Authors Liang, Huajie, Li, Ziyou, Liu, Zhaocong, Li, Qiang, Zhang, Shihong, Zhang, Zhenyu, Wang, Jinxiong, Jiang, Jianbo, Zhou, Chichun
Format Journal Article
LanguageEnglish
Published Beijing John Wiley & Sons, Inc 01.04.2025
Wiley
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Ultra‐high‐voltage direct current wall bushings are critical components in direct current transmission systems. Temperature variations and abnormal distributions can signal potential equipment failures that threaten system stability. Therefore, monitoring these critical multi‐point temperature variations is essential. However, the unique design of the bushings, featuring insulation sheds of periodic shape, distorts infrared temperature measurements by introducing interference points. These interference points, dependent on the measurement's angle and distance, appear irregularly in infrared images, severely impacting the accuracy of multi‐point temperature distribution assessments. To address this challenge, an anomaly detection method is proposed that adaptively identifies interference points. The method identifies interference points by comparing pixels and uses a voting mechanism to improve identification accuracy. Compared with traditional methods, this approach presents two main advantages: adaptive identification capability, which enables it to recognise interference points and adapt to changing conditions, and unsupervised learning, which enables it to work effectively without requiring manually labelled data. Experimental tests on 161 bushing infrared images demonstrate the effectiveness of the method, achieving a 100% success rate in identifying localised overheating issues. The method has been integrated into high‐voltage direct current transmission anomaly systems and can be used to monitor critical equipment, enhancing system reliability and safety.
Bibliography:Associate Editor
Jin Li
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ISSN:2397-7264
2096-9813
2397-7264
DOI:10.1049/hve2.70007