Distribution and Detection of Radiopaque Beads after Hepatic Transarterial Embolization in Swine: Cone-Beam CT versus MicroCT

To determine the true distribution of radiopaque beads (ROBs) after hepatic embolization in swine as imaged by micro-computed tomography (microCT) compared with in vivo cone-beam computerized tomography (CT) imaged at different kVp settings. Swine (n = 3) underwent hepatic transarterial embolization...

Full description

Saved in:
Bibliographic Details
Published inJournal of vascular and interventional radiology Vol. 29; no. 4; pp. 568 - 574
Main Authors Thompson, John G., van der Sterren, William, Bakhutashvili, Ivane, van der Bom, Imramsjah M., Radaelli, Alessandro G., Karanian, John W., Esparza-Trujillo, Juan, Woods, David L., Lewis, Andrew L., Wood, Bradford J., Pritchard, William F.
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.04.2018
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:To determine the true distribution of radiopaque beads (ROBs) after hepatic embolization in swine as imaged by micro-computed tomography (microCT) compared with in vivo cone-beam computerized tomography (CT) imaged at different kVp settings. Swine (n = 3) underwent hepatic transarterial embolization (n = 6) with the use of 70–150-μm ROBs under fluoroscopic guidance. After stasis, in vivo cone-beam CT was performed at 120, 100, and 80 kVp. The animal was euthanized, the liver resected, and microCT with 17 μm resolution performed on embolized tissue samples. The resulting cone-beam CT and microCT data were segmented and registered. Total vessel length, minimum volume–enclosing ellipsoid (MVEE), and number of independent volumes were measured. Maximum-intensity projections (MIPs) were generated for each cone-beam CT. Metrics for all cone-beam CT segmentations differed significantly from microCT segmentations. Segmentations at 80 kVp presented significantly greater vessel length, MVEE, and number of independent volumes compared with 100 kVp and 120 kVp. In addition, 100 kVp segmentations presented significantly greater vessel length than 120 kVp. MIPs presented greater visualization than cone-beam CT segmentations and improved as kVp decreased. The full ROB distribution was more extensive than was apparent on cone-beam CT. Quantitative measures of embolic distribution demonstrated significantly better correlation with microCT with decreasing kVp. Similarly, qualitative analysis of MIPs showed improved visualization of beads with decreasing kVp. These findings demonstrate the clinical value of 80 kVp and 100 kVp protocols in the imaging of radiopaque embolizations compared with 120 kVp. However, considerations on X-ray penetration and dose may favor use of 100 kVp imaging over 80 kVp.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1051-0443
1535-7732
DOI:10.1016/j.jvir.2017.11.011